English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Using the etalon effect for in situ balancing of the Advanced Virgo arm cavities

Hild, S., Freise, A., Mantovani, M., Chelkowski, S., Degallaix, J., & Schilling, R. (2009). Using the etalon effect for in situ balancing of the Advanced Virgo arm cavities. Classical and Quantum Gravity, 26(2): 025005. doi:10.1088/0264-9381/26/2/025005.

Item is

Files

show Files
hide Files
:
cqg9_2_025005.pdf (Publisher version), 177KB
Name:
cqg9_2_025005.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
eDoc_access: PUBLIC
License:
-

Locators

show

Creators

show
hide
 Creators:
Hild, Stefan1, Author           
Freise, A., Author
Mantovani, M., Author
Chelkowski, S., Author
Degallaix, Jerome1, Author           
Schilling, Roland1, Author           
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Content

show
hide
Free keywords: -
 Abstract: Several large-scale interferometric gravitational-wave detectors use resonant arm cavities to enhance the light power in the interferometer arms. These cavities are based on different optical designs: One design uses wedged input mirrors to create additional optical pick-off ports for deriving control signals. The second design employs input mirrors without wedge and thus offers the possibility of using the etalon effect inside the input mirrors for tuning the finesse of the arm cavities. In this paper, we introduce a concept of maximum flexibility that combines both of these options, by featuring wedges at the input mirrors and using the etalon effect instead in the end mirrors. We present a design for the arm cavities of Advanced Virgo. The paper focusses on evaluating the influence of etalon imperfections onto the overall Advanced Virgo performance. We use numerical simulations to derive requirements for the manufacturing accuracy of an end mirror etalon for Advanced Virgo. Furthermore, we give analytical approximations for the achievable tuning range of an imperfect etalon depending on the curvature and orientation mismatch of the two etalon surfaces. We evaluate the displacement noise originating from temperature driven optical phase noise of the etalon. In addition the influence of the etalon effect onto other Advanced Virgo subsystems such as the alignment sensing and control is analysed.

Details

show
hide
Language(s):
 Dates: 2009-01-21
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Classical and Quantum Gravity
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 26 (2) Sequence Number: 025005 Start / End Page: - Identifier: ISSN: 0264-9381