  The influence of flow and motion in MRI of diffusion using a modified CE-FAST sequence.

Merboldt, K. D., Hänicke, W., Gyngell, M., Frahm, J., & Bruhn, H. (1989). The influence of flow and motion in MRI of diffusion using a modified CE-FAST sequence. Magnetic Resonance in Medicine, 12(2), 198-208. doi:10.1002/mrm.1910120206.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2376697.pdf (Verlagsversion), 650KB
Name:
2376697.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Merboldt, K. D.1, Autor           
Hänicke, W.1, Autor           
Gyngell, M.L.1, Autor           
Frahm, J.1, Autor           
Bruhn, H.1, Autor           
Affiliations:
1Research Group of Biomedical NMR, MPI for Biophysical Chemistry, Max Planck Society, ou_578633              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Severe motion and flow artifacts are a problem in MRI of diffusion in vivo due to the application of strong magnetic field gradients. Here it is shown that image artifacts can be removed by using a modified fast-scan MRI sequence (CE-FAST) in conjunction with averaging of diffusion-weighted images. In phantom studies slow (coherent) flow (<1 mm s-1) in the presence of strong diffusion gradients is shown to cause signal losses in diffusion-weighted images that depend on the relative orientations of the flow direction and the diffusion gradient. On the other hand, pulsatile motions of macroscopic dimensions (e.g. 1 mm, 1 Hz, in-plane) lead to smearing and ghosting of signal intensities along the phase-encoding direction of the images. In both phantoms and rabbit brains in vivo motion artifacts were found to be reducible by averaging 8-16 images. Unfortunately. the resulting image contrast no longer represents a “true” diffusion contrast but is affected by additional signal losses due to motion averaging. All experiments were performed on a 40-cm-borc 2.35-T Bruker Medspee system.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 1989-11
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mrm.1910120206
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 12 (2) Artikelnummer: - Start- / Endseite: 198 - 208 Identifikator: -