Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  A Microstrip Resonator for Animal MRI at 16.4T

Shajan, G., Balla, D., Hoffmann, J., & Pohmann, R. (2008). A Microstrip Resonator for Animal MRI at 16.4T. Poster presented at ESMRMB 2008 Congress: 25th Annual Meeting, Valencia, Spain.

Item is

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Shajan, G1, 2, Autor           
Balla, DZ1, 2, Autor           
Hoffmann, J1, 2, Autor           
Pohmann, R1, 2, Autor           
Affiliations:
1Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528700              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Introduction: MRI is increasingly moving towards higher magnetic field because
of the inherent high sensitivity and greater spectroscopic resolution.
To realize these advantages, the front end, the RF coil and the receive chain,
needs to be optimized. A Quadrature Microstrip Transmission Line (MTL)
resonator was built and SNR is compared with a commercially available
shielded linear birdcage coil. This work also includes development of a TR
switch module (consisting of T/R switch and preamplifier) and a Microstrip
transmission line based Quadrature hybrid.
Subjects and Methods: Experiments were performed on a 16.4T/26cm horizontal
bore Magnex Magnet attached to a Bruker biospec Spectrometer. The
imaging gradient system has an inner diameter of 12cms.
The resonator (Figure 1) is built on Teflon cylinder with wall thickness 5mm.
It consists of 8 equally spaced λ/2 MTL resonators. Electromagnetic coupling
among the 8 resonators makes the entire MTL volume coil resonate at the
desired frequency. In this case, each resonator is tuned to 725MHz to resonate
the volume coil to 705MHz in the unloaded condition.
The TR switch module consists of a diode network and a 2 stage low noise
amplifier (LNA). The first stage of the LNA has PHEMT ATF35143 and the
second stage has BJT BFR193. The TR switch module has a gain of 30dB and
noise figure of 1.1dB at 698MHz.
Results: The losses in the receive chain is reduced by connecting the TR
switch module closer to the birdcage coil. An SNR gain of 1.4X is observed as
shown in Table 1. The MTL resonator has double the volume of the birdcage
resonator and has comparable SNR as that of the birdcage resonator (Table
1). The linear and combined phantom images are shown in Figure 2. Figure
3 shows in-vivo Axial and Sagittal rat brain RARE images with in-plane spatial
resolution of 117μm.
Conclusion: A Quadrature MTL resonator with good SNR and signal uniformity
has been built. This paves the way for developing actively decoupled
resonators and to use smaller receive only surface coils for improved
Sensitivity at 16.4T.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2008-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/s10334-008-0126-2
BibTex Citekey: 5335
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: ESMRMB 2008 Congress: 25th Annual Meeting
Veranstaltungsort: Valencia, Spain
Start-/Enddatum: 2008-10-02 - 2008-10-04

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Materials in Physics, Biology and Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : No longer published by Elsevier
Seiten: - Band / Heft: 21 (Supplement 1) Artikelnummer: 912 Start- / Endseite: 449 - 450 Identifikator: ISSN: 0968-5243