日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Adaptive denoising for chemical exchange saturation transfer MR imaging

Breitling, J., Deshmane, A., Goerke, S., Korzowski, A., Herz, K., Ladd, M., Scheffler, K., Bachert, P., & Zaiss, M. (2019). Adaptive denoising for chemical exchange saturation transfer MR imaging. NMR in Biomedicine, 32(11), 1-14. doi:10.1002/nbm.4133.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0004-6D97-8 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0004-F6BF-0
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Breitling, J, 著者
Deshmane, A1, 2, 著者           
Goerke, S, 著者
Korzowski, A, 著者
Herz, K1, 2, 著者           
Ladd, ME, 著者
Scheffler, K1, 2, 著者           
Bachert, P, 著者
Zaiss, M1, 2, 著者           
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: High image signal–to–noise ratio (SNR) is required to reliably detect the inherently small chemical exchange saturation transfer (CEST) effects in vivo. In this study, it was demonstrated that identifying spectral redundancies of CEST data by principal component analysis (PCA) in combination with an appropriate data–driven extraction of relevant information can be used for an effective and robust denoising of CEST spectra. The relationship between the number of relevant principal components and SNR was studied on fitted in vivo Z–spectra with artificially introduced noise. Three different data–driven criteria to automatically determine the optimal number of necessary components were investigated. In addition, these criteria facilitate straightforward assessment of data quality that could provide guidance for CEST MR protocols in terms of SNR. Insights were applied to achieve a robust denoising of highly sampled low power Z–spectra of the human brain at 3 and 7 T. The median criterion provided the best estimation for the optimal number of components consistently for all three investigated artificial noise levels. Application of the denoising technique to in vivo data revealed a considerable increase in image quality for the amide and rNOE contrast with a considerable SNR gain. At 7 T the denoising capability was quantified to be comparable or even superior to an averaging of six measurements. The proposed denoising algorithm enables an efficient and robust denoising of CEST data by combining PCA with appropriate data–driven truncation criteria. With this generally applicable technique at hand, small CEST effects can be reliably detected without the need for repeated measurements.

資料詳細

表示:
非表示:
言語:
 日付: 2019-072019-11
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/nbm.4133
eDoc: e4133
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: NMR in Biomedicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: London : Heyden & Son
ページ: - 巻号: 32 (11) 通巻号: - 開始・終了ページ: 1 - 14 識別子(ISBN, ISSN, DOIなど): ISSN: 0952-3480
CoNE: https://pure.mpg.de/cone/journals/resource/954925574973