Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  0.3-second FLASH MRI of the human heart.

Frahm, J., Merboldt, K. D., Bruhn, H., Gyngell, M. L., Haenicke, W., & Chien, D. (1990). 0.3-second FLASH MRI of the human heart. Magnetic Resonance in Medicine, 13(1), 150-157. doi:10.1002/mrm.1910130114.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
603081.pdf (Verlagsversion), 537KB
Name:
603081.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Frahm, J.1, Autor           
Merboldt, K. D.1, Autor           
Bruhn, H.1, Autor           
Gyngell, M. L.1, Autor           
Haenicke, W.1, Autor           
Chien, D.1, Autor           
Affiliations:
1Research Group of Biomedical NMR, MPI for Biophysical Chemistry, Max Planck Society, ou_578633              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Flow-suppressed FLASH MR images of the human heart have been recorded within a measuring time of 0.3 s using a 2.0-T whole-body research system (Siemens Magnetom) equipped with a conventional 10 mT m-1 gradient system. Subsecond imaging times have been achieved by reducing the repetition time to TR = 4.8 ms and by lowering the spatial resolution to 64 X 128 measured data points. The flip angle of the slice-selective radiofrequency (rf) pulses was adjusted to 10 degrees. Cardiac chambers, ventricular walls, and valves are well delineated in images from a single cardiac cycle using a field of 250 mm and a slice thickness of 8 mm. No motion artifacts were observed as a consequence of the short echo time of TE = 2.8 ms. Distinction between flowing blood and solid structures has been achieved by spatial presaturation of adjacent slices using two slice-selective 90 degrees rf pulses preceding the entire imaging sequence.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 1990-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mrm.1910130114
ISI: A1990CJ68300013
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 13 (1) Artikelnummer: - Start- / Endseite: 150 - 157 Identifikator: ISSN: 0740-3194