日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  On the error analyses of polarization measurements of the white-light coronagraph aboard ASO-S

Feng, L., Li, H., Inhester, B., Chen, B., Ying, B.-L., Lu, L., & Gan, W. (2019). On the error analyses of polarization measurements of the white-light coronagraph aboard ASO-S. Research in Astronomy and Astrophysics, 19(4):. doi:10.1088/1674-4527/19/4/59.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0003-C521-9 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0003-C522-8
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Feng, Li, 著者
Li, Hui, 著者
Inhester, Bernd1, 著者           
Chen, Bo, 著者
Ying, Bei-Li, 著者
Lu, Lei, 著者
Gan, Weiqun, 著者
所属:
1Department Sun and Heliosphere, Max Planck Institute for Solar System Research, Max Planck Society, ou_1832289              

内容説明

表示:
非表示:
キーワード: -
 要旨: The Advanced Space-based Solar Observatory (ASO-S) mission aims to explore the two most spectacular eruptions on the Sun: solar flares and coronal mass ejections (CMEs), and their magnetism. For the study of CMEs, the payload Lyman-alpha Solar Telescope (LST) has been proposed. It includes a traditional white-light coronagraph and a Lyman-alpha coronagraph which opens a new window to CME observations. Polarization measurements taken by white-light coronagraphs are crucial for deriving fundamental physical parameters of CMEs. To make such measurements, there are two options for a Stokes polarimeter which have been applied by existing white-light coronagraphs for space missions. One uses a single or triple linear polarizer, the other involves both a half-wave plate and a linear polarizer.We find that the former option is subject to less uncertainty in the derived Stokes vector propagating from detector noise. The latter option involves two plates which are prone to internal reflections and may have a reduced transmission factor. Therefore, the former option is adopted as our Stokes polarimeter scheme for LST. Based on the parameters of the intended linear polarizer(s) colorPol provided by CODIXX and the half-wave plate 2-APW-L2-012C by Altechna, it is further shown that the imperfect maximum transmittance of the polarizer significantly increases the variance amplification of Stokes vector by at least about 50% when compared with the ideal case. The relative errors of Stokes vector caused by the imperfection of colorPol polarizer and the uncertainty due to the polarizer assembly in the telescope are estimated to be about 5%. Among the considered parameters, we find that the dominant error comes from the uncertainty in the maximum transmittance of the polarizer.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2019
 出版の状態: オンラインで出版済み
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1088/1674-4527/19/4/59
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Research in Astronomy and Astrophysics
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Institute of Physics Publishing (IOP)
ページ: - 巻号: 19 (4) 通巻号: 059 開始・終了ページ: - 識別子(ISBN, ISSN, DOIなど): ISSN: 1674-4527
CoNE: https://pure.mpg.de/cone/journals/resource/1674-4527