English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Erratum: Quality assessment of MEG-to-MRI coregistrations

Sonntag, H., Haueisen, J., & Maess, B. (2018). Erratum: Quality assessment of MEG-to-MRI coregistrations. Physics in Medicine and Biology, 63(10): 109601. doi:10.1088/1361-6560/aabf4e.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Sonntag, Hermann1, Author           
Haueisen, Jens2, 3, Author
Maess, Burkhard1, Author           
Affiliations:
1Methods and Development Unit MEG and EEG: Signal Analysis and Modelling , MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634559              
2Institute for Biomedical Engineering and Informatics, TU Ilmenau, Germany, ou_persistent22              
3Hans Berger Clinic for Neurology, Jena University Hospital, Germany, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: For high precision in source reconstruction of magnetoencephalography (MEG) or electroencephalography data, high accuracy of the coregistration of sources and sensors is mandatory. Usually, the source space is derived from magnetic resonance imaging (MRI). In most cases, however, no quality assessment is reported for sensor-to-MRI coregistrations. If any, typically root mean squares (RMS) of point residuals are provided. It has been shown, however, that RMS of residuals do not correlate with coregistration errors. We suggest using target registration error (TRE) as criterion for the quality of sensor-to-MRI coregistrations. TRE measures the effect of uncertainty in coregistrations at all points of interest. In total, 5544 data sets with sensor-to-head and 128 head-to-MRI coregistrations, from a single MEG laboratory, were analyzed. An adaptive Metropolis algorithm was used to estimate the optimal coregistration and to sample the coregistration parameters (rotation and translation). We found an average TRE between 1.3 and 2.3 mm at the head surface. Further, we observed a mean absolute difference in coregistration parameters between the Metropolis and iterative closest point algorithm of $(1.9 \pm 15){\hspace{0pt}}^{\circ}$ and $(1.1 \pm 9)$ m. A paired sample t-test indicated a significant improvement in goal function minimization by using the Metropolis algorithm. The sampled parameters allowed computation of TRE on the entire grid of the MRI volume. Hence, we recommend the Metropolis algorithm for head-to-MRI coregistrations.

Details

show
hide
Language(s): eng - English
 Dates: 2018-05-10
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1088/1361-6560/aabf4e
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Physics in Medicine and Biology
  Other : Phys. Med. Biol.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: London? : IOP Pub.
Pages: - Volume / Issue: 63 (10) Sequence Number: 109601 Start / End Page: - Identifier: ISSN: 0031-9155
CoNE: https://pure.mpg.de/cone/journals/resource/954925433410