Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Slice accelerated gradient-echo spin-echo dynamic susceptibility contrast imaging with blipped CAIPI for increased slice coverage

Eichner, C., Jafari-Khouzani, K., Cauley, S., Bhat, H., Polaskova, P., Andronesi, O. C., et al. (2014). Slice accelerated gradient-echo spin-echo dynamic susceptibility contrast imaging with blipped CAIPI for increased slice coverage. Magnetic Resonance in Medicine, 72(3), 770-778. doi:10.1002/mrm.24960.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Eichner, Cornelius1, Autor           
Jafari-Khouzani, Kourosh 2, Autor
Cauley, Stephen2, Autor
Bhat, Himanshu3, Autor
Polaskova, Pavlina2, Autor
Andronesi, Ovidiu C.2, Autor
Rapalino, Otto2, Autor
Turner, Robert1, Autor           
Wald, Lawrence L.2, Autor
Setsompop, Kawim2, Autor
Stufflebeam, Steven2, Autor
Affiliations:
1Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_persistent22              
2Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA, ou_persistent22              
3Siemens Healthcare Sector, Charlestown, MA, USA, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: DSC; GESE; CAIPIRINHA; blipped CAIPI; SMS; Brain tumor
 Zusammenfassung: Purpose: To improve slice coverage of gradient echo spin echo (GESE) sequences for dynamic susceptibility contrast (DSC) MRI using a simultaneous-multiple-slice (SMS) method.

Methods: Data were acquired on 3 Tesla (T) MR scanners with a 32-channel head coil. To evaluate use of SMS for DSC, an SMS GESE sequence with two-fold slice coverage and same temporal sampling was compared with a standard GESE sequence, both with 2× in-plane acceleration. A signal to noise ratio (SNR) comparison was performed on one healthy subject. Additionally, data with Gadolinium injection were collected on three patients with glioblastoma using both sequences, and perfusion analysis was performed on healthy tissues as well as on tumor.

Results: Retained SNR of SMS DSC is 90% for a gradient echo (GE) and 99% for a spin echo (SE) acquisition, compared with a standard acquisition without slice acceleration. Comparing cerebral blood volume maps, it was observed that the results of standard and SMS acquisitions are comparable for both GE and SE images.

Conclusion: Two-fold slice accelerated DSC MRI achieves similar SNR and perfusion metrics as a standard acquisition, while allowing a significant increase in slice coverage of the brain. The results also point to a possibility to improve temporal sampling rate, while retaining the same slice coverage.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-08-292013-07-172013-08-302013-10-282014-09
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mrm.24960
PMID: 24285593
PMC: PMC4002660
Anderer: Epub 2013
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 72 (3) Artikelnummer: - Start- / Endseite: 770 - 778 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149