Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Speedmeter scheme for gravitational-wave detectors based on EPR quantum entanglement

Knyazev, E., Danilishin, S., Hild, S., & Khalili, F. Y. (2018). Speedmeter scheme for gravitational-wave detectors based on EPR quantum entanglement. Physics Letters A, 382(33), 2219-2225. doi:10.1016/j.physleta.2017.10.009.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1701.01694.pdf (Preprint), 332KB
Name:
1701.01694.pdf
Beschreibung:
File downloaded from arXiv at 2018-08-06 09:53
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
:
PLA382_2219.pdf (Verlagsversion), 560KB
Name:
PLA382_2219.pdf
Beschreibung:
Open Access
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Knyazev, E., Autor
Danilishin, S.1, Autor           
Hild, S., Autor
Khalili, F. Ya., Autor
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: General Relativity and Quantum Cosmology, gr-qc,Quantum Physics, quant-ph
 Zusammenfassung: We propose a new implementation of a quantum speed meter QND measurement scheme. It employs two independent optical readouts of the interferometer test masses, featuring strongly different values of the bandwidths $\gamma_{1,2}$ and of the optical circulating power $I_{1,2}$, with the special relationship of $I_1/I_2=\gamma_1/\gamma_2$. The outputs of these two position meters have to be combined by an additional beamsplitter. In this scheme, signals at the common and the differential outputs of the interferometer setup are proportional to the position and the velocity of the test masses, respectively. The influence of the position meter-like back action force associated with the position signal can be cancelled using the EPR approach by measuring the amplitude quadrature of the beamsplitter common output correlated with this force. In the standard signal-recycled Michelson interferometer topology of the modern gravitational-wave detectors, two independent optical position meters can be implemented by two orthogonal polarisations of the probe light. Our analysis shows that the EPR speedmeter provides significantly improved sensitivity for all frequencies below $\sim 30\,{\rm Hz}$ compared to an equivalent signal recycled Michelson interferometer. We believe the EPR speedmeter scheme to be very attractive for future upgrades of gravitational wave detectors, because it requires only minor changes to be implemented in the interferometer hardware and allows to switch between the position meter and the speed meter modes within short time-scales and without any changes to the hardware.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2017-01-062018
 Publikationsstatus: Erschienen
 Seiten: 14 pages, 5 figures
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physics Letters A
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 382 (33) Artikelnummer: - Start- / Endseite: 2219 - 2225 Identifikator: -