English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Calibration of X-ray telescope prototypes at PANTER

Liao, Y.-Y., Shen, Z.-X., Yu, J., Huang, Q.-S., Ma, B., Zhang, Z., et al. (2019). Calibration of X-ray telescope prototypes at PANTER. Research in Astronomy and Astrophysics, 19(12): 172. doi:10.1088/1674–4527/19/12/172.

Item is

Files

show Files
hide Files
:
Calibration of X-ray telescope prototypes at PANTER.pdf (Any fulltext), 7MB
 
File Permalink:
-
Name:
Calibration of X-ray telescope prototypes at PANTER.pdf
Description:
-
OA-Status:
Visibility:
Private
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Liao, Ying-Yu, Author
Shen, Zheng-Xiang, Author
Yu, Jun, Author
Huang, Qiu-Shi, Author
Ma, Bin, Author
Zhang, Zhong, Author
Wang, Xiao-Qiang, Author
Wang, Kun, Author
Xie, Chun, Author
Burwitz, Vadim1, Author           
Hartner, Gisela1, Author           
La Caria, Marlis-Madeleine1, Author           
Pelliciari, Carlo1, Author           
Wang, Zhan-Shan, Author
Affiliations:
1High Energy Astrophysics, MPI for Extraterrestrial Physics, Max Planck Society, ou_159890              

Content

show
hide
Free keywords: -
 Abstract: We report on a ground X-ray calibration of two X-ray telescope prototypes at the PANTER X-ray Test Facility, operated by the Max-Planck-Institute for Extraterrestrial Physics, in Neuried, Germany. The X-ray telescope prototypes were developed by the Institute of Precision Optical Engineering (IPOE) of Tongji University, in a conical Wolter-I configuration, using thermal glass slumping technology. Prototype #1 with three layers and Prototype #2 with 21 layers were tested to assess the prototypes' on-axis imaging performance. The measurement of Prototype #1 indicates a Half Power Diameter (HPD) of 82'' at 1.49 keV. As for Prototype #2, we performed more comprehensive measurements of on-axis angular resolution and effective area at several energies ranging from 0.5–10 keV. The HPD and effective area are 111'' and 39 cm2 at 1.49 keV, respectively, at which energy the on-axis performance of the prototypes is our greatest concern.

Details

show
hide
Language(s): eng - English
 Dates: 2019-12
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1088/1674–4527/19/12/172
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Research in Astronomy and Astrophysics
  Alternative Title : Res. Astron. Astrophys.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 19 (12) Sequence Number: 172 Start / End Page: - Identifier: ISSN: 1674-4527