Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Towards MRI temperature mapping in real time-the proton resonance frequency method with undersampled radial MRI and nonlinear inverse reconstruction.

Zhang, Z., Michaelis, T., & Frahm, J. (2017). Towards MRI temperature mapping in real time-the proton resonance frequency method with undersampled radial MRI and nonlinear inverse reconstruction. Quantitative Imaging in Medicine and Surgery, 7(2), 251-258. doi:10.21037/qims.2017.03.03.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2451012.pdf (Verlagsversion), 2MB
Name:
2451012.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Zhang, Z.1, Autor           
Michaelis, T.1, Autor           
Frahm, J.1, Autor           
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Hyperthermia; temperature mapping; thermometry; radial MRI; real-time MRI
 Zusammenfassung: Background: Optimal control of minimally invasive interventions by hyperthermia requires dynamic temperature mapping at high temporal resolution. Methods: Based on the temperature-dependent shift of the proton resonance frequency (PRF), this work developed a method for real-time MRI thermometry which relies on highly undersampled radial FLASH MRI sequences with iterative image reconstruction by regularized nonlinear inversion (NLINV). As a first step, the method was validated with use of a temperature phantom and ex vivo organs (swine kidney) subjected to heating by warm water or a pulsed laser source. Results: The temperature maps obtained by real-time PRF MRI demonstrate good accuracy as independently controlled by fiber-optic temperature sensors. Moreover, the dynamic results demonstrate both excellent sensitivity to single laser pulses (20 ms duration, 6 J energy output) and high temporal resolution, i.e., 200 ms acquisition times per temperature map corresponding to a rate of 5 frames per second. In addition, future extensions to in vivo applications were prepared by addressing the breathingrelated motion problem by a pre-recorded library of reference images representative of all respiratory states. Conclusions: The proposed method for real-time MRI thermometry now warrants further developments towards in vivo MRI monitoring of thermal interventions in animals.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2017-042017-04
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.21037/qims.2017.03.03
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Quantitative Imaging in Medicine and Surgery
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 7 (2) Artikelnummer: - Start- / Endseite: 251 - 258 Identifikator: -