Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Mid-infrared laser-induced fluorescence with nanosecond time resolution using a superconducting nanowire single-photon detector: New technology for molecular science.

Chen, L., Schwarzer, D., Verma, V. B., Stevens, M. J., Marsili, F., Mirin, R. P., et al. (2017). Mid-infrared laser-induced fluorescence with nanosecond time resolution using a superconducting nanowire single-photon detector: New technology for molecular science. Accounts of Chemical Research, 50(6), 1400-1409. doi:10.1021/acs.accounts.7b00071.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2451333.pdf (Verlagsversion), 3MB
 
Datei-Permalink:
-
Name:
2451333.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (UNKNOWN id 303; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2451333_Suppl.pdf (Ergänzendes Material), 880KB
Name:
2451333_Suppl.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Chen, L.1, Autor           
Schwarzer, D.1, Autor           
Verma, V. B., Autor
Stevens, M. J., Autor
Marsili, F., Autor
Mirin, R. P., Autor
Nam, S. W., Autor
Wodtke, A. M.1, Autor           
Affiliations:
1Department of Dynamics at Surfaces, MPI for Biophysical Chemistry, Max Planck Society, ou_578600              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: In contrast to UV photomultiplier tubes that are widely used in physical chemistry, mid-infrared detectors are notorious for poor sensitivity and slow time response. This helps explain why, despite the importance of infrared spectroscopy in molecular science, mid-infrared fluorescence is not more widely used. In recent years, several new technologies have been developed that open new experimental possibilities for research in the mid-infrared. In this Account, we present one of the more promising technologies, superconducting nanowire single photon detectors (SNSPDs) by sharing our experience with its use in a typical experiment carried out by physical chemists (laser-induced fluorescence) and comparing the SNSPD to a detector commonly used by physical chemists (InSb at LN Temperature). SNSPDs are fabricated from a thin film of superconducting metal, patterned into a meandering nanowire. The nanowire is cooled below its superconducting temperature, Tc, and held in a constant current circuit below the critical current necessary to destroy superconductivity, Ic. Upon absorption of a photon, the resulting heat is sufficient to destroy superconductivity across the entire width of the nanowire, an event that can be detected as a voltage pulse. In contrast to semiconductor-based detectors, which have a long wavelength cutoff determined by the band gap, the SNSPD exhibits single-photon sensitivity across the entire mid-IR spectrum. As these devices have not been used extensively outside the field of light detection technology research, one important goal of this Account is to provide practical details for the implementation of these devices in a physical chemistry laboratory. We provide extensive Supporting Information describing what is needed. This includes information on a liquid nitrogen cooled monochromator, the optical collection system including mid-infrared fibers, as well as a closed-cycle cryogenic cooler that reaches 0.3 K. We demonstrate the advantages of these detectors in a time-resolved laser-induced infrared fluorescence experiment on the energy pooling in crystalline CO overlayers formed on a NaCl(100) surface. We present dispersed fluorescence spectra recorded from 1.9 to 7.0 μm obtained by single-photon counting. We also estimate the sensitivity of this WSi-based detection system at 3 μm; the system's noise equivalent power (NEP) value is ∼10-3 of a conventional InSb photovoltaic device. Straightforward modifications are expected to provide another 100 000-fold improvement. We demonstrate that the temporal resolution of the experiment is limited only by the pulse duration of the laser used in this work (fwhm = 3.7 ns). The use of SNSPDs enables dramatically improved observations of energy pooling in cryogenic molecular crystals.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2017-06-022017
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1021/acs.accounts.7b00071
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Accounts of Chemical Research
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 50 (6) Artikelnummer: - Start- / Endseite: 1400 - 1409 Identifikator: -