  A fluorescence-based assay for exopeptidases using self-quenching peptide probes with single-molecule sensitivity

Marmé, N., Weston, K. D., Staudt, T., Spatz, J. P., & Knemeyer, J.-P. (2005). A fluorescence-based assay for exopeptidases using self-quenching peptide probes with single-molecule sensitivity. International Journal of Environmental Analytical Chemistry, 85(9-11), 741-751. doi:10.1080/03067310500147720.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文
その他のタイトル : Intern. J. Environ. Anal. Chem.

ファイル

表示: ファイル
非表示: ファイル
:
IntJEnvironmentalAnalytChem_85_2005_741.pdf (全文テキスト(全般)), 438KB
 
ファイルのパーマリンク:
-
ファイル名:
IntJEnvironmentalAnalytChem_85_2005_741.pdf
説明:
-
OA-Status:
閲覧制限:
制限付き (Max Planck Institute for Medical Research, MHMF; )
MIMEタイプ / チェックサム:
application/pdf
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

作成者

表示:
非表示:
 作成者:
Marmé, Nicole, 著者
Weston, Kenneth D., 著者
Staudt, Thorsten, 著者
Spatz, Joachim P.1, 2, 著者           
Knemeyer, Jens-Peter, 著者
所属:
1Cellular Biophysics, Max Planck Institute for Medical Research, Max Planck Society, ou_2364731              
2Biophysical Chemistry, Institute of Physical Chemistry, University of Heidelberg, 69120 Heidelberg, Germany, ou_persistent22              

内容説明

表示:
非表示:
キーワード: Exopeptidase-assay; Self-quenching substrates; Single-molecule imaging
 要旨: In recent years, the interest in assaying exopeptidases has become increasingly important because they are significantly involved in many diseases like cancer. To date, no generally applicable fluorescence-based detection method has been developed because commercially available doubly-labeled substrates are not always digested by exopeptidases. In this article we present a new method for the sensitive detection of exopeptidases based on fluorescently-labeled substrates containing only one fluorophore that is efficiently quenched by an adjacent tryptophan residue via photoinduced electron transfer. Because of their well-known properties we chose carboxypeptidase A (CPA) as a model system. The self-quenching probes were used in homogeneous solution as well as on cross-linked PEG-coated surfaces in combination with single-molecule imaging techniques. However, even with standard fluorescence spectrometers we achieved sensitivity below the picomolar range.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2004-10-042005-03-112007-01-252005
 出版の状態: 出版
 ページ: 11
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): eDoc: 240004
DOI: 10.1080/03067310500147720
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: International Journal of Environmental Analytical Chemistry
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: New York : Gordon and Breach.
ページ: - 巻号: 85 (9-11) 通巻号: - 開始・終了ページ: 741 - 751 識別子(ISBN, ISSN, DOIなど): ISSN: 0306-7319
CoNE: https://pure.mpg.de/cone/journals/resource/954925515508