  Characterization of fine resolution field spectrometers using solar Fraunhofer lines and atmospheric absorption features

Meroni, M., Busetto, L., Guanter, L., Cogliati, S., Crosta, G. F., Migliavacca, M., et al. (2010). Characterization of fine resolution field spectrometers using solar Fraunhofer lines and atmospheric absorption features. Applied Optics, 49(15), 2858-2871. doi:10.1364/AO.49.002858.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
BEX489.pdf (Verlagsversion), 2MB
 
Datei-Permalink:
-
Name:
BEX489.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Meroni, Michele, Autor
Busetto, Lorenzo, Autor
Guanter, Luis, Autor
Cogliati, Sergio, Autor
Crosta, Giovanni Franco, Autor
Migliavacca, Mirco1, Autor           
Panigada, Cinzia, Autor
Rossini, Micol, Autor
Colombo, Roberto, Autor
Affiliations:
1External Organizations, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: SPECTRAL CALIBRATION; IMAGING SPECTROMETERS; NETWORK; AVIRISOptics;
 Zusammenfassung: The accurate spectral characterization of high-resolution spectrometers is required for correctly computing, interpreting, and comparing radiance and reflectance spectra acquired at different times or by different instruments. In this paper, we describe an algorithm for the spectral characterization of field spectrometer data using sharp atmospheric or solar absorption features present in the measured data. The algorithm retrieves systematic shifts in channel position and actual full width at half-maximum (FWHM) of the instrument by comparing data acquired during standard field spectroscopy measurement operations with a reference irradiance spectrum modeled with the MODTRAN4 radiative transfer code. Measurements from four different field spectrometers with spectral resolutions ranging from 0.05 to 3.5 nm are processed and the results validated against laboratory calibration. An accurate retrieval of channel position and FWHM has been achieved, with an average error smaller than the instrument spectral sampling interval. (C) 2010 Optical Society of America

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2010
 Publikationsstatus: Erschienen
 Seiten: 14
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: Anderer: BEX489
DOI: 10.1364/AO.49.002858
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Applied Optics
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Washington, DC : Optical Society of America
Seiten: - Band / Heft: 49 (15) Artikelnummer: - Start- / Endseite: 2858 - 2871 Identifikator: ISSN: 0003-6935
CoNE: https://pure.mpg.de/cone/journals/resource/991042728167604