Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Defining the human hypothalamus in vivo by ultra-high field 7 Tesla MRI

Schindler, S., Schmidt, L., Strauß, M., Anwander, A., Bazin, P.-L., Trampel, R., et al. (2013). Defining the human hypothalamus in vivo by ultra-high field 7 Tesla MRI. Klinische Neurophysiologie, 44(1), P65-P65. doi:10.1055/s-0033-1337206.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Schindler, Stephanie, Autor
Schmidt, Laura, Autor
Strauß, Maria, Autor
Anwander, Alfred1, Autor           
Bazin, Pierre-Louis2, Autor           
Trampel, Robert2, Autor           
Möller, Harald E.3, Autor           
Hegerl, Ulrich, Autor
Turner, Robert2, Autor           
Geyer, Stefan2, Autor           
Schönknecht, Peter, Autor
Affiliations:
1Department Neuropsychology, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634551              
2Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634550              
3Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Introduction: Post mortem studies have shown a volume deficit of the hypothalamus in depressive patients. With ultra-high field (7 Tesla) MRI this effect can now be investigated in vivo in detail. But to benefit from the sub-millimeter resolution a segmentation procedure was required that overcomes limitations of existing procedures, in particular schematic approximations. Methods: Using 7 Tesla T1 images the traditional anatomical landmarks of the hypothalamus were refined. A detailed segmentation algorithm (unilateral hypothalamus) was developed for colour coded, histogram-matched images and evaluated in a sample of 10 subjects. Intra- and interrater reliabilities were estimated in terms of intra- and interclass-correlation coefficients (ICC). Results: The computer-assisted segmentation algorithm ensured test-retest reliabilities of ICC ≥0.97 and interrater-reliabilities of ICC ≥0.94. There were no significant volume differences between the tracers and between the hemispheres (paired t-tests). The estimated volume of the hypothalamus (tracer 1, first run) was 1130.64 mm3± 103.48 mm3. Conclusion: We present a computer-assisted algorithm for the manual segmentation of the human hypothalamus on ultra-high field 7 Tesla MR images. With very high intra- and interrater reliabilities it outperforms former procedures established with 1.5 T or 3 T MRI. The estimated volumes lie between previous histological and neuroimaging results. The algorithm provides an excellent basis for the investigation of our larger neuropsychiatric sample. It can be used by fellow researchers and it can serve as a gold standard for future automated procedures.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-03-212013-03-21
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1055/s-0033-1337206
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 57. Jahrestagung der Deutschen Gesellschaft für Klinische Neurophysiologie: DGKN
Veranstaltungsort: Leipzig, Germany
Start-/Enddatum: 2013-03-21 - 2013-03-23

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Klinische Neurophysiologie
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Stuttgart : Thieme
Seiten: - Band / Heft: 44 (1) Artikelnummer: - Start- / Endseite: P65 - P65 Identifikator: ISSN: 1434-0275
CoNE: https://pure.mpg.de/cone/journals/resource/954925623269