日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Decoupling of a double‐row 16‐element tight‐fit transceiver phased array for human whole‐brain imaging at 9.4 T

Avdievich, N., Giapitzakis, I., Pfrommer, A., Shajan, G., Scheffler, K., & Henning, A. (2018). Decoupling of a double‐row 16‐element tight‐fit transceiver phased array for human whole‐brain imaging at 9.4 T. NMR in Biomedicine, 31(9), 1-13. doi:10.1002/nbm.3964.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0001-A8D6-0 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0001-F926-C
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Avdievich, N1, 2, 著者           
Giapitzakis, IA1, 2, 著者           
Pfrommer, A1, 2, 著者           
Shajan, G2, 3, 著者           
Scheffler, K2, 3, 著者           
Henning, A1, 2, 著者           
所属:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
3Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: One of the major challenges in constructing multi‐channel and multi‐row transmit (Tx) or transceiver (TxRx) arrays is the decoupling of the array's loop elements. Overlapping of the surface loops allows the decoupling of adjacent elements and also helps to improve the radiofrequency field profile by increasing the penetration depth and eliminating voids between the loops. This also simplifies the design by reducing the number of decoupling circuits. At the same time, overlapping may compromise decoupling by generating high resistive (electric) coupling near the overlap, which cannot be compensated for by common decoupling techniques. Previously, based on analytical modeling, we demonstrated that electric coupling has strong frequency and loading dependence, and, at 9.4 T, both the magnetic and electric coupling between two heavily loaded loops can be compensated at the same time simply by overlapping the loops. As a result, excellent decoupling was obtained between adjacent loops of an eight‐loop single‐row (1 × 8) human head tight‐fit TxRx array. In this work, we designed and constructed a 9.4‐T (400‐MHz) 16‐loop double‐row (2 × 8) overlapped TxRx head array based on the results of the analytical and numerical electromagnetic modeling. We demonstrated that, simply by the optimal overlap of array loops, a very good decoupling can be obtained without additional decoupling strategies. The constructed TxRx array provides whole‐brain coverage and approximately 1.5 times greater Tx efficiency relative to a transmit‐only/receive‐only (ToRo) array, which consists of a larger Tx‐only array and a nested tight‐fit 31‐loop receive (Rx)‐only array. At the same time, the ToRo array provides greater peripheral signal‐to‐noise ratio (SNR) and better Rx parallel performance in the head–feet direction. Overall, our work provides a recipe for a simple, robust and very Tx‐efficient design suitable for parallel transmission and whole‐brain imaging at ultra‐high fields.

資料詳細

表示:
非表示:
言語:
 日付: 2018-072018-09
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/nbm.3964
eDoc: e3964
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: NMR in Biomedicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: London : Heyden & Son
ページ: - 巻号: 31 (9) 通巻号: - 開始・終了ページ: 1 - 13 識別子(ISBN, ISSN, DOIなど): ISSN: 0952-3480
CoNE: https://pure.mpg.de/cone/journals/resource/954925574973