  Evaluation of transmit efficiency and SAR for a tight fit transceiver human head phased array at 9.4 T

Avdievich, N., Hoffmann, J., Shajan, G., Pfrommer, A., Giapitzakis, I., Scheffler, K., et al. (2017). Evaluation of transmit efficiency and SAR for a tight fit transceiver human head phased array at 9.4 T. NMR in Biomedicine, 30(2), 1-12. doi:10.1002/nbm.3680.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
Link (beliebiger Volltext)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Avdievich, NI1, 2, Autor           
Hoffmann, J2, 3, Autor           
Shajan, G2, 3, Autor           
Pfrommer, A1, 2, Autor           
Giapitzakis, IA1, 2, Autor           
Scheffler, K2, 3, Autor           
Henning, A1, 2, Autor           
Affiliations:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
3Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Ultra-high field (UHF, ≥7 T) tight fit transceiver phased arrays improve transmit (Tx) efficiency (B1+/√P) in comparison with Tx-only arrays, which are usually larger to fit receive (Rx)-only arrays inside. One of the major problems limiting applications of tight fit arrays at UHFs is the anticipated increase of local tissue heating, which is commonly evaluated by the local specific absorption rate (SAR). To investigate the tradeoff between Tx efficiency and SAR when a tight fit UHF human head transceiver phased array is used instead of a Tx-only/Rx-only RF system, a single-row eight-element prototype of a 400 MHz transceiver head phased array was constructed. The Tx efficiency and SAR of the array were evaluated and compared with that of a larger Tx-only array, which could also be used in combination with an 18-channel Rx-only array. Data were acquired on the Siemens Magnetom whole body 9.4 T human MRI system. Depending on the head size, positioning and the RF shim strategy, the smaller array provides from 11 to 23 higher Tx efficiency. In general, the Tx performance, evaluated as B1+/√SAR, i.e. the safety excitation efficiency (SEE), is also not compromised. The two arrays provide very similar SEEs evaluated over 1000 random RF shim sets. We demonstrated that, in general, the tight fit transceiver array improves Tx performance without compromising SEE. However, in specific cases, the SEE value may vary, favoring one of the arrays, and therefore must be carefully evaluated.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2017-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/nbm.3680
BibTex Citekey: AvdievichHSGSH2016
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: NMR in Biomedicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 30 (2) Artikelnummer: - Start- / Endseite: 1 - 12 Identifikator: eDoc: e3680