日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  A Simple Approach of Combined Passive and Active Shimming for In Vivo MR Spectroscopy at High Magnetic Field

Juchem, C., Logothetis, N., & Pfeuffer, J. (2006). A Simple Approach of Combined Passive and Active Shimming for In Vivo MR Spectroscopy at High Magnetic Field. Poster presented at 14th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM 2006), Seattle, WA, USA.

Item is

基本情報

表示: 非表示:
資料種別: ポスター

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Juchem, C1, 2, 著者           
Logothetis, NK1, 2, 著者           
Pfeuffer, J1, 2, 著者           
所属:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: High magnetic fields increase are advantageous for MRS, since sensitivity and spectral dispersion are increased, however, spectral peaks are also broadened in vivo due to stronger susceptibility-induced effects. The shim requirements on our 7T monkey system exceeded the capabilities for active shimming tenfold, which were overcome by the optimized combination of passive and active shimming. Simple ferro-shim geometries of only two pieces per shim term were numerically optimized to generate the second order spherical harmonic shim fields. The removal of large scale field inhomogeneities was achieved by mounting the ferro-shims on a cylinder surface that surrounded the monkey head and the RF coils. Subsequently, high accuracy adjustment of the active shims was done with FASTMAP. The experimental effort for the passive shimming was acceptable, the shimming was reproducible between
sessions; no eddy current or spike artifacts were introduced. The presented methods are of high practical relevance for shimming on high field systems and/or shimming of anatomical regions which inherently require high shim fields.

資料詳細

表示:
非表示:
言語:
 日付: 2006-05
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): BibTex参照ID: 3829
 学位: -

関連イベント

表示:
非表示:
イベント名: 14th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM 2006)
開催地: Seattle, WA, USA
開始日・終了日: 2006-05-06 - 2006-05-12

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: 14th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM 2006)
種別: 会議論文集
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: - 通巻号: 1394 開始・終了ページ: 286 識別子(ISBN, ISSN, DOIなど): -