Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  MultiNet PyGRAPPA: Multiple neural networks for reconstructing variable density GRAPPA (a 1H FID MRSI study)

Nassirpour, S., Chang, P., & Henning, A. (2018). MultiNet PyGRAPPA: Multiple neural networks for reconstructing variable density GRAPPA (a 1H FID MRSI study). NeuroImage, 183, 336-345. doi:10.1016/j.neuroimage.2018.08.032.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Nassirpour, S1, 2, Autor           
Chang, P1, 2, Autor           
Henning, A1, 2, Autor           
Affiliations:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Magnetic resonance spectroscopic imaging (MRSI) is a powerful tool for mapping metabolite levels across the brain, however, it generally suffers from long scan times. This severely hinders its application in clinical settings. Additionally, the presence of nuisance signals (e.g. the subcutaneous lipid signals close to the skull region in brain metabolite mapping) makes it challenging to apply conventional acceleration techniques to shorten the scan times. The goal of this work is, therefore, to increase the overall applicability of high resolution metabolite mapping using 1H MRSI by introducing a novel GRAPPA acceleration acquisition/reconstruction technique. An improved reconstruction method (MultiNet) is introduced that uses machine learning, specifically neural networks, to reconstruct accelerated data. The method is further modified to use more neural networks with nonlinear hidden layers and is then combined with a variable density undersampling scheme (MultiNet PyGRAPPA) to enable higher in-plane acceleration factors of R = 5.6 and R = 7 for a non-lipid suppressed ultra-short TR and TE 1H FID MRSI sequence. The proposed method is evaluated for high resolution metabolite mapping of the human brain at 9.4T. The results show that the proposed method is superior to conventional GRAPPA: there is no significant residual lipid aliasing artifact in the images when the proposed MultiNet method is used. Furthermore, the MultiNet PyGRAPPA acquisition/reconstruction method with R = 5.6 results in reproducible high resolution metabolite maps (with an in-plane matrix size of 64 × 64) that can be acquired in 2.8 min on 9.4T. In conclusion, using multiple neural networks to predict the missing points in GRAPPA reconstruction results in a more reliable data recovery while keeping the noise levels under control. Combining this high fidelity reconstruction with variable density undersampling (MultiNet PyGRAPPA) enables higher in-plane acceleration factors even for non-lipid suppressed 1H FID MRSI, without introducing any structured aliasing artifact in the image.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2018-082018-12
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1016/j.neuroimage.2018.08.032
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: NeuroImage
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Orlando, FL : Academic Press
Seiten: - Band / Heft: 183 Artikelnummer: - Start- / Endseite: 336 - 345 Identifikator: ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166