Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Combination of a multimode antenna and TIAMO for traveling-wave imaging at 9.4 Tesla

Hoffmann, J., Mirkes, C., Shajan, G., Scheffler, K., & Pohmann, R. (2016). Combination of a multimode antenna and TIAMO for traveling-wave imaging at 9.4 Tesla. Magnetic Resonance in Medicine, 75(1), 452-462. doi:10.1002/mrm.25614.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
Link (beliebiger Volltext)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Hoffmann, J1, 2, Autor           
Mirkes, C1, 2, Autor           
Shajan, G1, 2, Autor           
Scheffler, K1, 2, Autor           
Pohmann, R1, 2, Autor           
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose
To investigate the performance of a multimode antenna combined with time-interleaved acquisition of modes (TIAMO) for improved 1H image homogeneity as compared to conventional traveling-wave imaging in the human brain at 9.4 Tesla (T).
Methods
An adjustable three-port antenna was built to stimulate the propagation of three basic waveguide modes within a 9.4 T scanner bore. For TIAMO, two time-interleaved acquisitions using different linear combinations of these modes were optimized to achieve a homogeneous rooted sum-of-squares combination of their inline image patterns ( inline image). The antenna's transmit and receive performance, as well as local specific absorption rate, were analyzed using experiments and numerical simulations.
Results
The optimized TIAMO inline image combination was superior to radiofrequency shimming. Across the entire brain, it improved the homogeneity of the excitation field by a factor of two and its maximum-to-minimum ratio by almost a factor of five as compared to the circularly polarized mode. The two-fold increase in “virtual” receive channels enhanced the parallel imaging performance and enabled the use of higher acceleration factors.
Conclusion
Despite the limited number of channels, a remote three-port antenna combined with TIAMO represents an easily implementable setup to achieve void-free 1H images from the entire brain at 9.4 T, which can be used for anatomical localization and B0 shimming.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2016-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.25614
BibTex Citekey: HoffmannMSSP2015
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 75 (1) Artikelnummer: - Start- / Endseite: 452 - 462 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149