  ERETIC with automatic phase adjustment and eddy current correction compensation

Zoelch, N., Fuchs A, Boesiger, P., Fuchs, A., Boesiger, P., & Henning, A. (2012). ERETIC with automatic phase adjustment and eddy current correction compensation. Magnetic Resonance Materials in Physics, Biology and Medicine, 25(Supplement 1), 302-303.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Zoelch, N, Author
Fuchs A, Boesiger, P, Author
Fuchs, A, Author
Boesiger, P, Author
Henning, A1, Author           
Affiliations:
1Institute for Biomedical Engineering, University and ETH Zürich, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Purpose/Introduction: With ERETIC (Electrical REference To access Invivo Concentrations) the areas of the metabolite resonances are converted into absolute concentrations by comparing them to an artificially generated signal [1, 2]. As a further development and simplification of the phantom replacement method [3] it has, especially in the presence of lesions or pathological disorders, considerable advantages compared to methods using internal references [4]. Since Eddy currents, arising from switching field gradients, falsify the quantification results, it is highly desirable to be able to use ERETIC as reference also in eddy current corrected spectra. In this work, we combine ERETIC and the eddy current correction proposed by Klose [5] with no need for additional post processing. Subjects and Methods: In the ERETIC setup (1H MRS) used here [2] the electrical reference signal is generated by the spectrometer itself. An amplitude modulated RF pulse is sent through an auxiliary channel and transmitted over an optical system to the coil, where it is demodulated and coupled inductively to the receive coil over a small loop [Fig. 3]. To avoid lineshape distortions of the ERETIC peak in the eddy current corrected spectra [Fig. 2], the used RF pulse is modified. Directly after the water reference scan the time-dependent phase of the complex water signal is calculated at every time point and added to the ERETIC signal by frequency modulation of the RF pulse. In a sense, an inverse Klose correction is thus applied to the ERETIC signal. This method was implemented in the control software of a Philips Achieva 3T human MRI scanner (Philips Healthcare, Best, The Netherlands). All signals were corrected for eddy current effects using the Klose approach and fitted using LCModel with simulated basis sets. Results: With the modifications for the ERETIC signal proposed here, the ERETIC peak is automatically in phase with all the other metabolites and shows no line distortion in eddy current corrected spectra [Fig. 4]. Therefore the ERETIC peak can be simultaneously fitted with commercially available algorithms without the need of changing fit parameters from scan to scan. Discussion/Conclusion: In conclusion, the usability of ERETIC was increased by implementing an automatic phase correction and eddy current correction compensation. With this, fitting and data handling become far less demanding, which is an important step towards clinical applicability of ERETIC.

Details

show
hide
Language(s):
 Dates: 2012-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s10334-012-0323-x
BibTex Citekey: ZoelchFBH2012
 Degree: -

Event

show
hide
Title: 29th Annual Scientific Meeting ESMRMB 2012
Place of Event: Lisboa, Portugal
Start-/End Date: -

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Materials in Physics, Biology and Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : No longer published by Elsevier
Pages: - Volume / Issue: 25 (Supplement 1) Sequence Number: - Start / End Page: 302 - 303 Identifier: ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532