English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Analytical modeling provides new insight into complex mutual coupling between surface loops at ultrahigh fields

Avdievich, N., Pfrommer, A., Giapitzakis, I., & Henning, A. (2017). Analytical modeling provides new insight into complex mutual coupling between surface loops at ultrahigh fields. NMR in Biomedicine, 30(10), 1-13. doi:10.1002/nbm.3759.

Item is

Files

show Files

Locators

show
hide
Locator:
Link (Any fulltext)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Avdievich, N1, 2, Author           
Pfrommer, A1, 2, Author           
Giapitzakis, IA1, 2, Author           
Henning, A1, 2, Author           
Affiliations:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Ultrahigh-field (UHF) (≥7 T) transmit (Tx) human head surface loop phased arrays improve both the Tx efficiency (B1+/√P) and homogeneity in comparison with single-channel quadrature Tx volume coils. For multi-channel arrays, decoupling becomes one of the major problems during the design process. Further insight into the coupling between array elements and its dependence on various factors can facilitate array development. The evaluation of the entire impedance matrix Z for an array loaded with a realistic voxel model or phantom is a time-consuming procedure when performed using electromagnetic (EM) solvers. This motivates the development of an analytical model, which could provide a quick assessment of the Z-matrix. In this work, an analytical model based on dyadic Green's functions was developed and validated using an EM solver and bench measurements. The model evaluates the complex coupling, including both the electric (mutual resistance) and magnetic (mutual inductance) coupling. Validation demonstrated that the model does well to describe the coupling at lower fields (≤3 T). At UHFs, the model also performs well for a practical case of low magnetic coupling. Based on the modeling, the geometry of a 400-MHz, two-loop transceiver array was optimized, such that, by simply overlapping the loops, both the mutual inductance and the mutual resistance were compensated at the same time. As a result, excellent decoupling (below −40 dB) was obtained without any additional decoupling circuits. An overlapped array prototype was compared (signal-to-noise ratio, Tx efficiency) favorably to a gapped array, a geometry which has been utilized previously in designs of UHF Tx arrays.

Details

show
hide
Language(s):
 Dates: 2017-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/nbm.3759
BibTex Citekey: AvdievichPGH2017
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: NMR in Biomedicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 30 (10) Sequence Number: - Start / End Page: 1 - 13 Identifier: eDoc: e3759