English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Quantitative measurement of combustion gases in harsh environments using NDIR spectroscopy.

Niklas, C., Bauke, S., Müller, F., Golibrzuch, K., Wackerbarth, H., & Ctistis, G. (2019). Quantitative measurement of combustion gases in harsh environments using NDIR spectroscopy. Journal of Sensors and Sensor Systems, 8(1), 123-132. doi:10.5194/jsss-8-123-2019.

Item is

Files

show Files
hide Files
:
3030683.pdf (Publisher version), 4MB
Name:
3030683.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-

Locators

show

Creators

show
hide
 Creators:
Niklas,, C., Author
Bauke, S., Author
Müller, F., Author
Golibrzuch, K.1, Author           
Wackerbarth, H., Author
Ctistis, G., Author
Affiliations:
1Department of Dynamics at Surfaces, MPI for biophysical chemistry, Max Planck Society, ou_578600              

Content

show
hide
Free keywords: -
 Abstract: The global climate change calls for more environmentally friendly use of energy and has led to stricter limits and regulations for the emissions of various greenhouse gases. Consequently, there is nowadays an increasing need for the detection of exhaust and natural gases. This need leads to an ever-growing market for gas sensors, which, at the moment, is dominated by chemical sensors. Yet, the increasing demands to also measure under harsh environmental conditions pave the way for non-invasive measurements and thus optical detection techniques. Here, we present the development of two optical detection systems using non-dispersive infrared absorption spectroscopy (NDIR). One system is intended for civilian use, capable of detecting both CO as well as CO2 in the range of 4–5 µm. Furthermore, restrictions regarding size and economic viability are put on this sensor so it can compete with existing sensors. For CO2, an estimated resolution of 444 ppm is achieved, which is competitive with established sensors on the market. For CO an estimated resolution of 1401 ppm was achieved, rendering it necessary to improve this sensor to be competitive with other available sensors. The second system is used in an exhaust system and is capable of detecting CO2 at 3.2 µm facing cross-sensitivity with H2O. A data analysis method is described to separate the CO2 and H2O signals, revealing a time resolution of 33 µs.

Details

show
hide
Language(s): eng - English
 Dates: 2019-03-01
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.5194/jsss-8-123-2019
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Sensors and Sensor Systems
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 8 (1) Sequence Number: - Start / End Page: 123 - 132 Identifier: -