Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  New applications of TrueFISP in cardiovascular magnetic resonance imaging: three-dimensional TrueFISP and inversion recovery TrueFISP

Scheffler, K., & Hennig, J. (2000). New applications of TrueFISP in cardiovascular magnetic resonance imaging: three-dimensional TrueFISP and inversion recovery TrueFISP. Poster presented at International MR Angio Club, XII International Workshop on MRA, Lyon, France.

Item is

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Scheffler, K1, Autor           
Hennig, J, Autor
Affiliations:
1External Organizations, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Three-dimensional TrueFISP: The TrueFISP sequence as proposed by Oppelt et al. in 1986 offers a
high contrast between myocardium and intraventricular
cavity, which is desirable for accurate assessment of
ventricular function. A significant drawback of True-
FISP is its sensitivity to off-resonance effects caused by
an imperfect shim, chemical shifts, eddy currents, and
Maxwell effects. An extension of the two-dimensional
TrueFISP sequence to an ECG gated three-dimensional
TrueFISP sequence is thus not straight forward and
requires a very carefully designed acquisition scheme.
The current implementation of our gated three-dimensional
TrueFISP sequence allows to acquire the complete
heart in its diastolic phase within about 20
heartbeats with a resolution of 2 x 2 x 3 mm. In addition,
a three-dimensional TrueFISP cine technique with
a time resolution of 80 ms and a spatial resolution of
3 x 4 x 4 mm was implemented.
hTcersion recoveo" TrueFISP: Two-dimensional inversion
recovery TrueFISP is a new method for T1 quantification
of the myocard within several heartbeats. The
intrinsically T~ weighted FLASH readout module was
replaced by a TrueFISP readout module to continuously
acquire the recovery of longitudinal magnetization
alter inversion or saturation. Quantitative T~
measurements on phantoms and on humans based on
FLASH and TrueFISP were compared to the gold standard of separately acquired TI measurements. Applications of IR TrueFISP may include quantitative assessment of myocard damage after CA administration.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2001-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/BF02678272
BibTex Citekey: SchefflerH2001_2
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: International MR Angio Club, XII International Workshop on MRA
Veranstaltungsort: Lyon, France
Start-/Enddatum: 2000-10-04 - 2000-10-07

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Materials in Physics, Biology and Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : No longer published by Elsevier
Seiten: - Band / Heft: 12 (1) Artikelnummer: - Start- / Endseite: 62 Identifikator: ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532