  CEST MR-Fingerprinting: practical considerations and insights for acquisition schedule design and improved reconstruction

Perlman, O., Herz, K., Zaiss, M., Cohen, O., Rosen, M., & Farrar, C. (2020). CEST MR-Fingerprinting: practical considerations and insights for acquisition schedule design and improved reconstruction. Magnetic Resonance in Medicine, 83(2), 462-478. doi:10.1002/mrm.27937.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Perlman, O, Autor
Herz, K1, 2, Autor           
Zaiss, M1, 2, Autor           
Cohen, O, Autor
Rosen, MS, Autor
Farrar, CT, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose
To understand the influence of various acquisition parameters on the ability of CEST MR‐Fingerprinting (MRF) to discriminate different chemical exchange parameters and to provide tools for optimal acquisition schedule design and parameter map reconstruction.
Methods

Numerical simulations were conducted using a parallel computing implementation of the Bloch‐McConnell equations, examining the effect of TR, TE, flip‐angle, water urn:x-wiley:07403194:media:mrm27937:mrm27937-math-0011 and urn:x-wiley:07403194:media:mrm27937:mrm27937-math-0012, saturation‐pulse duration, power, and frequency on the discrimination ability of CEST‐MRF. A modified Euclidean distance matching metric was evaluated and compared to traditional dot product matching. L‐Arginine phantoms of various concentrations and pH were scanned at 4.7T and the results compared to numerical findings.
Results

Simulations for dot product matching demonstrated that the optimal flip‐angle and saturation times are urn:x-wiley:07403194:media:mrm27937:mrm27937-math-0013 and 1100 ms, respectively. The optimal maximal saturation power was 3.4 μT for concentrated solutes with a slow exchange rate, and 5.2 μT for dilute solutes with medium‐to‐fast exchange rates. Using the Euclidean distance matching metric, much lower maximum saturation powers were required (1.6 and 2.4 μT, respectively), with a slightly longer saturation time (1500 ms) and urn:x-wiley:07403194:media:mrm27937:mrm27937-math-0014 flip‐angle. For both matching metrics, the discrimination ability increased with the repetition time. The experimental results were in agreement with simulations, demonstrating that more than a 50% reduction in scan‐time can be achieved by Euclidean distance‐based matching.
Conclusions

Optimization of the CEST‐MRF acquisition schedule is critical for obtaining the best exchange parameter accuracy. The use of Euclidean distance‐based matching of signal trajectories simultaneously improved the discrimination ability and reduced the scan time and maximal saturation power required.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2019-042019-072019-082020-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.27937
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 83 (2) Artikelnummer: - Start- / Endseite: 462 - 478 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149