Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  A realistic vascular model for BOLD signal up to 16.4 T

Müller-Bierl, B., Pawlak, V., Kerr, J., Ugurbil, K., & Uludag, K. (2010). A realistic vascular model for BOLD signal up to 16.4 T. Poster presented at ISMRM-ESMRMB Joint Annual Meeting 2010, Stockholm, Sweden.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
ISMRM-2010-1129.PDF (beliebiger Volltext), 475KB
Name:
ISMRM-2010-1129.PDF
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Müller-Bierl, B1, 2, Autor           
Pawlak, V2, 3, 4, Autor           
Kerr, J2, 3, 4, Autor           
Ugurbil, K, Autor
Uludag, K1, 2, Autor           
Affiliations:
1Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528700              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              
3Former Research Group Network Imaging, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528697              
4Research Group Neural Population Imaging, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497807              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The blood oxygenation level-dependent (BOLD) signal using functional magnetic resonance imaging (fMRI) is currently the most popular imaging
method to study brain function non-invasively. The sensitivity of the BOLD signal to different types of MRI sequences and vessel sizes is currently under
investigation [1]. Gradient echo (GRE) sequences are known to be sensitive to larger vessels (venules and veins), whereas spin-echo (SE) sequences
are generally more sensitive to smaller vessels (venules and capillaries), especially at high magnetic field strength [2, 3]. However, the widely used
single vessel model is only an approximation to the realistic vascular distribution. Realistic vascular models have been proposed by Marques and
Bowtell [4] and, recently, by Chen et al.[5]. We herein present a realistic vascular model (RVM) where diffusion is accounted for by a Monte-Carlo
random walk.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2010-05
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: MullerBierlPKUU2012
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: ISMRM-ESMRMB Joint Annual Meeting 2010
Veranstaltungsort: Stockholm, Sweden
Start-/Enddatum: 2010-05-01 - 2010-05-07

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: ISMRM-ESMRMB Joint Annual Meeting 2010
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: 1129 Start- / Endseite: - Identifikator: -