日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Erratum: Quality assessment of MEG-to-MRI coregistrations

Sonntag, H., Haueisen, J., & Maess, B. (2018). Erratum: Quality assessment of MEG-to-MRI coregistrations. Physics in Medicine and Biology, 63(10):. doi:10.1088/1361-6560/aabf4e.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0001-795C-1 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0003-8986-B
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Sonntag, Hermann1, 著者           
Haueisen, Jens2, 3, 著者
Maess, Burkhard1, 著者           
所属:
1Methods and Development Unit MEG and EEG: Signal Analysis and Modelling , MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634559              
2Institute for Biomedical Engineering and Informatics, TU Ilmenau, Germany, ou_persistent22              
3Hans Berger Clinic for Neurology, Jena University Hospital, Germany, ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 要旨: For high precision in source reconstruction of magnetoencephalography (MEG) or electroencephalography data, high accuracy of the coregistration of sources and sensors is mandatory. Usually, the source space is derived from magnetic resonance imaging (MRI). In most cases, however, no quality assessment is reported for sensor-to-MRI coregistrations. If any, typically root mean squares (RMS) of point residuals are provided. It has been shown, however, that RMS of residuals do not correlate with coregistration errors. We suggest using target registration error (TRE) as criterion for the quality of sensor-to-MRI coregistrations. TRE measures the effect of uncertainty in coregistrations at all points of interest. In total, 5544 data sets with sensor-to-head and 128 head-to-MRI coregistrations, from a single MEG laboratory, were analyzed. An adaptive Metropolis algorithm was used to estimate the optimal coregistration and to sample the coregistration parameters (rotation and translation). We found an average TRE between 1.3 and 2.3 mm at the head surface. Further, we observed a mean absolute difference in coregistration parameters between the Metropolis and iterative closest point algorithm of $(1.9 \pm 15){\hspace{0pt}}^{\circ}$ and $(1.1 \pm 9)$ m. A paired sample t-test indicated a significant improvement in goal function minimization by using the Metropolis algorithm. The sampled parameters allowed computation of TRE on the entire grid of the MRI volume. Hence, we recommend the Metropolis algorithm for head-to-MRI coregistrations.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2018-05-10
 出版の状態: オンラインで出版済み
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1088/1361-6560/aabf4e
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Physics in Medicine and Biology
  その他 : Phys. Med. Biol.
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: London? : IOP Pub.
ページ: - 巻号: 63 (10) 通巻号: 109601 開始・終了ページ: - 識別子(ISBN, ISSN, DOIなど): ISSN: 0031-9155
CoNE: https://pure.mpg.de/cone/journals/resource/954925433410