English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Dynamic B0 shimming of the motor cortex and cerebellum with a multicoil shim setup for BOLD fMRI at 9.4T

Aghaeifar, A., Bause, J., Leks, E., Grodd, W., & Scheffler, K. (2020). Dynamic B0 shimming of the motor cortex and cerebellum with a multicoil shim setup for BOLD fMRI at 9.4T. Magnetic Resonance in Medicine, 83(5), 1730-1740. doi:10.1002/mrm.28044.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Aghaeifar, A1, 2, Author           
Bause, J1, 2, Author           
Leks, E1, 2, Author           
Grodd, W1, 2, Author           
Scheffler, K1, 2, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: PURPOSE: We assessed how improved static magnetic field (B0 ) homogeneity with a dynamic multicoil shimming can influence the blood oxygen level dependent (BOLD) contrast to noise when echo planar imaging (EPI) sequence is used for a motor task functional MRI study. We showed that a multicoil shim setup can be a proper choice for dynamic shimming of 2 spatially distant areas with different inhomogeneity distributions.
METHODS: A 16-channel multicoil shim setup is used to provide improved B0 homogeneity by dynamic slice-wise shimming. The performance of dynamic B0 shimming was investigated in 2 distinct brain regions, the motor cortex and the cerebellum, in the same experiment during a finger-tapping task. Temporal SNR (tSNR), geometric distortion of the EPIs, and results of an analysis with a general linear model before and after shimming with the multicoil were compared.
RESULTS: Reduced B0 deviation by 30% and 52% in the cerebellum and motor cortex, respectively, resulted in higher tSNR and a reduction of distortions in the EPI. Statistical analysis applied to the EPIs showed higher t values and increased number of voxels above significance threshold when shimming with the multicoil setup.
CONCLUSIONS: Improved B0 homogeneity leads to higher tSNR and enhances the detection of BOLD signal.

Details

show
hide
Language(s):
 Dates: 2019-112020-05
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.28044
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 83 (5) Sequence Number: - Start / End Page: 1730 - 1740 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149