日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Quantitative magnetic resonance spectroscopy at 3T based on the principle of reciprocity

Zoelch, N., Hock, A., & Henning, A. (2018). Quantitative magnetic resonance spectroscopy at 3T based on the principle of reciprocity. NMR in Biomedicine, 31(5), 1-17. doi:10.1002/nbm.3875.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0001-7CB7-6 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0001-806F-2
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Zoelch, N, 著者
Hock, A, 著者
Henning, A1, 2, 3, 著者           
所属:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
3Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Quantification of magnetic resonance spectroscopy signals using the phantom replacement method requires an adequate correction of differences between the acquisition of the reference signal in the phantom and the measurement in vivo. Applying the principle of reciprocity, sensitivity differences can be corrected at low field strength by measuring the RF transmitter gain needed to obtain a certain flip angle in the measured volume. However, at higher field strength the transmit sensitivity may vary from the reception sensitivity, which leads to wrongly estimated concentrations. To address this issue, a quantification approach based on the principle of reciprocity for use at 3T is proposed and validated thoroughly. In this approach, the RF transmitter gain is determined automatically using a volume‐selective power optimization and complemented with information from relative reception sensitivity maps derived from contrast‐minimized images to correct differences in transmission and reception sensitivity. In this way, a reliable measure of the local sensitivity was obtained. The proposed method is used to derive in vivo concentrations of brain metabolites and tissue water in two studies with different coil sets in a total of 40 healthy volunteers. Resulting molar concentrations are compared with results using internal water referencing (IWR) and Electric REference To access In vivo Concentrations (ERETIC). With the proposed method, changes in coil loading and regional sensitivity due to B1 inhomogeneities are successfully corrected, as demonstrated in phantom and in vivo measurements. For the tissue water content, coefficients of variation between 2 and 3.5 were obtained (0.6–1.4 in a single subject). The coefficients of variation of the three major metabolites ranged from 3.4–14.5. In general, the derived concentrations agree well with values estimated with IWR. Hence, the presented method is a valuable alternative for IWR, without the need for additional hardware such as ERETIC and with potential advantages in diseased tissue.

資料詳細

表示:
非表示:
言語:
 日付: 2018-05
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/nbm.3875
BibTex参照ID: ZoelchHH2018
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: NMR in Biomedicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 31 (5) 通巻号: - 開始・終了ページ: 1 - 17 識別子(ISBN, ISSN, DOIなど): eDoc: e3875