English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  “Eyes Open - Eyes Closed” EEG/fMRI data set including dedicated “Carbon Wire Loop” motion detection channels

van der Meer, J., Pampel, A., van Someren, E., Ramautar, J., van der Werf, Y., Gomez-Herrero, G., et al. (2016). “Eyes Open - Eyes Closed” EEG/fMRI data set including dedicated “Carbon Wire Loop” motion detection channels. Data in Brief, 7, 990-994. doi:10.1016/j.dib.2016.03.001.

Item is

Files

show Files

Locators

show
hide
Locator:
Link (Any fulltext)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
van der Meer, J, Author
Pampel, A, Author
van Someren, E, Author
Ramautar, J, Author
van der Werf, Y, Author
Gomez-Herrero, G, Author
Lepsien, J, Author
Hellrung, L, Author
Möller, H, Author
Walter, M1, 2, Author           
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: This data set contains electroencephalography (EEG) data as well as simultaneous EEG with functional magnetic resonance imaging (EEG/fMRI) data. During EEG/fMRI, the EEG cap was outfitted with a hardware-based add-on consisting of carbon-wire loops (CWL). These yielded six extra׳CWL׳ signals related to Faraday induction of these loops in the main magnetic field “Measurement and reduction of motion and ballistocardiogram artefacts from simultaneous EEG and fMRI recordings” (Masterton et al., 2007) [1]. In this data set, the CWL data make it possible to do a direct regression approach to deal with the BCG and specifically He artifact. The CWL-EEG/fMRI data in this paper has been recorded on two MRI scanners with different Helium pump systems (4 subjects on a 3 T TIM Trio and 4 subjects on a 3T VERIO). Separate EEG/fMRI data sets have been recorded for the helium pump ON as well as the helium pump OFF conditions. The EEG-only data (same subjects) has been recorded for a motion artifact-free reference EEG signal outside of the scanner. This paper also links to an EEGlab “EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis” (Delorme and Makeig, 2004) [2] plugin to perform a CWL regression approach to deal with the He pump artifact, as published in the main paper “Carbon-wire loop based artifact correction outperforms post-processing EEG/fMRI corrections-A validation of a real-time simultaneous EEG/fMRI correction method” (van der Meer et al., 2016) [3].

Details

show
hide
Language(s):
 Dates: 2016-06
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.dib.2016.03.001
BibTex Citekey: vanderMeerPvRvGLHMW2016
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Data in Brief
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 7 Sequence Number: - Start / End Page: 990 - 994 Identifier: -