日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
 前へ次へ 
  New coil positioning method for interleaved transcranial magnetic stimulation (TMS)/functional MRI (fMRI) and its validation in a motor cortex study

Moisa, M., Pohmann, R., Ewald, L., & Thielscher, A. (2009). New coil positioning method for interleaved transcranial magnetic stimulation (TMS)/functional MRI (fMRI) and its validation in a motor cortex study. Journal of Magnetic Resonance Imaging, 29(1), 189-197. doi:10.1002/jmri.21611.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Moisa, M1, 2, 著者           
Pohmann, R1, 2, 著者           
Ewald, L, 著者
Thielscher, A1, 2, 著者           
所属:
1Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528700              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose To develop and test a novel method for the coil placement in interleaved Transcranial Magnetic Stimulation(TMS)/fMRI studies.
Materials and Methods Initially, a desired TMS coil position at the subject’s head is recorded using a neuronavigation system. Subsequently, a custom-made holding device is used for coil placement inside the MR scanner. The parameters of the device corresponding to the prerecorded position are automatically determined from a fast structural image acquired directly before the experiment. The spatial accuracy of our method was verified on a phantom. Finally, in a study on 5 subjects, the coil was placed above the cortical representation of a hand muscle in M1 and the BOLD responses to short rTMS trains were assessed using EPI recordings.
Results The spatial accuracy of our method is in the range of 2.9±1.3(SD) mm. Motor cortex stimulation resulted in robust BOLD activations in motor- and auditory-related brain areas, with the activation in M1 being localized in the hand knob.
Conclusion We present a user-friendly method for TMS coil positioning in the MR scanner that exhibits good spatial accuracy and speeds up the setup of the experiment. The motor-cortex study proves the viability of the approach and validates our interleaved TMS/fMRI setup.

資料詳細

表示:
非表示:
言語:
 日付: 2009-01
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/jmri.21611
BibTex参照ID: 5496
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Magnetic Resonance Imaging
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Chicago, IL : Society for Magnetic Resonance Imaging
ページ: - 巻号: 29 (1) 通巻号: - 開始・終了ページ: 189 - 197 識別子(ISBN, ISSN, DOIなど): ISSN: 1053-1807
CoNE: https://pure.mpg.de/cone/journals/resource/954925594512