Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  A 7T transmit and receive array combination for simultaneous investigation of electrophysiology and fMRI in non-human primates

Shajan, G., Balla, D., Steudel, T., Ehses, P., Merkle, H., Logothetis, N., et al. (2015). A 7T transmit and receive array combination for simultaneous investigation of electrophysiology and fMRI in non-human primates. Poster presented at 23rd Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2015), Toronto, Canada.

Item is

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
http://www.ismrm.org/15/program_files/MonEPS03.htm (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Shajan, G1, 2, Autor           
Balla, DZ1, 2, 3, Autor           
Steudel, T2, 3, Autor           
Ehses, P1, 2, Autor           
Merkle, H1, 2, Autor           
Logothetis, NK2, 3, Autor           
Pohmann, R1, 2, Autor           
Scheffler, K1, 2, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
3Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Simultaneous investigation of electrophysiology and fMRI in non-human primates presents several challenges on RF coil design. Transmit coil structure should allow access for electrodes from different orientations to allow recordings from different brain regions. Receive arrays must be designed around head posts fixed on the animal head, leading to non-optimum coil orientations in the helmet. In cases with more than one head posts, the receive array must be on two separable halves of the helmet. We developed an RF coil arrangement that optimizes the SNR and provides access for recordings from different regions of the brain.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2015-06
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: ShajanBSEMLPS2015
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 23rd Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2015)
Veranstaltungsort: Toronto, Canada
Start-/Enddatum: 2015-05-30 - 2015-06-05

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: 23rd Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2015)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: 3182 Start- / Endseite: - Identifikator: -