English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Adaptive denoising for chemical exchange saturation transfer MR imaging

Breitling, J., Deshmane, A., Goerke, S., Korzowski, A., Herz, K., Ladd, M., et al. (2019). Adaptive denoising for chemical exchange saturation transfer MR imaging. NMR in Biomedicine, 32(11), 1-14. doi:10.1002/nbm.4133.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Breitling, J, Author
Deshmane, A1, 2, Author           
Goerke, S, Author
Korzowski, A, Author
Herz, K1, 2, Author           
Ladd, ME, Author
Scheffler, K1, 2, Author           
Bachert, P, Author
Zaiss, M1, 2, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: High image signal–to–noise ratio (SNR) is required to reliably detect the inherently small chemical exchange saturation transfer (CEST) effects in vivo. In this study, it was demonstrated that identifying spectral redundancies of CEST data by principal component analysis (PCA) in combination with an appropriate data–driven extraction of relevant information can be used for an effective and robust denoising of CEST spectra. The relationship between the number of relevant principal components and SNR was studied on fitted in vivo Z–spectra with artificially introduced noise. Three different data–driven criteria to automatically determine the optimal number of necessary components were investigated. In addition, these criteria facilitate straightforward assessment of data quality that could provide guidance for CEST MR protocols in terms of SNR. Insights were applied to achieve a robust denoising of highly sampled low power Z–spectra of the human brain at 3 and 7 T. The median criterion provided the best estimation for the optimal number of components consistently for all three investigated artificial noise levels. Application of the denoising technique to in vivo data revealed a considerable increase in image quality for the amide and rNOE contrast with a considerable SNR gain. At 7 T the denoising capability was quantified to be comparable or even superior to an averaging of six measurements. The proposed denoising algorithm enables an efficient and robust denoising of CEST data by combining PCA with appropriate data–driven truncation criteria. With this generally applicable technique at hand, small CEST effects can be reliably detected without the need for repeated measurements.

Details

show
hide
Language(s):
 Dates: 2019-072019-11
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/nbm.4133
eDoc: e4133
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: NMR in Biomedicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: London : Heyden & Son
Pages: - Volume / Issue: 32 (11) Sequence Number: - Start / End Page: 1 - 14 Identifier: ISSN: 0952-3480
CoNE: https://pure.mpg.de/cone/journals/resource/954925574973