English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  High-resolution quantitative sodium imaging at 9.4 tesla

Mirkes, C., Hoffmann, J., Shajan, G., Pohmann, R., & Scheffler, K. (2015). High-resolution quantitative sodium imaging at 9.4 tesla. Magnetic Resonance in Medicine, 73(1), 342-351. doi:10.1002/mrm.25096.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Mirkes, CC1, 2, Author           
Hoffmann, J1, 2, Author           
Shajan, G1, 2, Author           
Pohmann, R1, 2, Author           
Scheffler, K1, 2, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose
Investigation of the feasibility to perform high-resolution quantitative sodium imaging at 9.4 Tesla (T).
Methods
A proton patch antenna was combined with a sodium birdcage coil to provide a proton signal without compromising the efficiency of the X-nucleus coil. Sodium density weighted images with a nominal resolution of 1 × 1 × 5 mm3 were acquired within 30 min with an ultrashort echo time sequence. The methods used for signal calibration as well as for B0, B1, and off-resonance correction were verified on a phantom and five healthy volunteers.
Results
An actual voxel volume of roughly 40 μL could be achieved at 9.4T, while maintaining an acceptable signal-to-noise ratio (8 for brain tissue and 35 for cerebrospinal fluid). The measured mean sodium concentrations for gray and white matter were 36 ± 2 and 31 ± 1 mmol/L of wet tissue, which are comparable to values previously reported in the literature.
Conclusion
The reduction of partial volume effects is essential for accurate measurement of the sodium concentration in the human brain. Ultrahigh field imaging is a viable tool to achieve this goal due to its increased sensitivity.

Details

show
hide
Language(s):
 Dates: 2015-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.25096
BibTex Citekey: MirkesHSPS2014
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 73 (1) Sequence Number: - Start / End Page: 342 - 351 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149