Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  RTbox: a device for highly accurate response time measurements

Li, X., Liang, Z., Kleiner, M., & Lu, Z.-L. (2010). RTbox: a device for highly accurate response time measurements. Behavior Research Methods, 42(1), 212-225. doi:10.3758/BRM.42.1.212.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Li, X, Autor
Liang, Z, Autor
Kleiner, M1, 2, 3, Autor           
Lu, Z-L, Autor
Affiliations:
1Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497797              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
3Project group: Cognitive Engineering, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528702              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Although computer keyboards and mice are frequently used in measuring response times (RTs), the accuracy of these measurements is quite low. Specialized RT collection devices must be used to obtain more accurate measurements. However, all the existing devices have some shortcomings. We have developed and implemented a new, commercially available device, the RTbox, for highly accurate RT measurements. The RTbox has its own microprocessor and high-resolution clock. It can record the identities and timing of button events with high accuracy, unaffected by potential timing uncertainty or biases during data transmission and processing in the host computer. It stores button events until the host computer chooses to retrieve them. The asynchronous storage greatly simplifies the design of user programs. The RTbox can also receive and record external signals as triggers and can measure RTs with respect to external events. The internal clock of the RTbox can be synchronized with the computer clock, so the device can be
used without external triggers. A simple USB connection is sufficient to integrate the RTbox with any standard computer and operating system.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2010-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.3758/BRM.42.1.212
BibTex Citekey: 6863
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Behavior Research Methods
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Austin, TX : Psychonomic Society
Seiten: - Band / Heft: 42 (1) Artikelnummer: - Start- / Endseite: 212 - 225 Identifikator: ISSN: 1554-3528
CoNE: https://pure.mpg.de/cone/journals/resource/1554-3528