English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Denoising spinal cord fMRI data: Approaches to acquisition and analysis

Eippert, F., Kong, Y., Jenkinson, M., Tracey, I., & Brooks, J. C. W. (2017). Denoising spinal cord fMRI data: Approaches to acquisition and analysis. NeuroImage, 154, 255-266. doi:10.1016/j.neuroimage.2016.09.065.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Eippert, Falk1, Author           
Kong, Yazhuo1, Author
Jenkinson, Mark1, Author
Tracey, Irene1, Author
Brooks, Jonathan C. W.2, Author
Affiliations:
1Oxford Centre for Functional Magnetic Resonance Imaging of the Brain, Nuffield Department of Clinical Neurosciences, University of Oxford, United Kingdom, ou_persistent22              
2Clinical Research and Imaging Centre, University of Bristol, United Kingdom, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Functional magnetic resonance imaging (fMRI) of the human spinal cord is a difficult endeavour due to the cord's small cross-sectional diameter, signal drop-out as well as image distortion due to magnetic field inhomogeneity, and the confounding influence of physiological noise from cardiac and respiratory sources. Nevertheless, there is great interest in spinal fMRI due to the spinal cord's role as the principal sensorimotor interface between the brain and the body and its involvement in a variety of sensory and motor pathologies. In this review, we give an overview of the various methods that have been used to address the technical challenges in spinal fMRI, with a focus on reducing the impact of physiological noise. We start out by describing acquisition methods that have been tailored to the special needs of spinal fMRI and aim to increase the signal-to-noise ratio and reduce distortion in obtained images. Following this, we concentrate on image processing and analysis approaches that address the detrimental effects of noise. While these include variations of standard pre-processing methods such as motion correction and spatial filtering, the main focus lies on denoising techniques that can be applied to task-based as well as resting-state data sets. We review both model-based approaches that rely on externally acquired respiratory and cardiac signals as well as data-driven approaches that estimate and correct for noise using the data themselves. We conclude with an outlook on techniques that have been successfully applied for noise reduction in brain imaging and whose use might be beneficial for fMRI of the human spinal cord.

Details

show
hide
Language(s): eng - English
 Dates: 2016-09-272016-09-282017-07-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/j.neuroimage.2016.09.065
PMID: 27693613
Other: Epub 2016
 Degree: -

Event

show

Legal Case

show

Project information

show hide
Project name : -
Grant ID : G0700399 ; G0700238
Funding program : -
Funding organization : Medical Research Council (MRC)

Source 1

show
hide
Title: NeuroImage
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Orlando, FL : Academic Press
Pages: - Volume / Issue: 154 Sequence Number: - Start / End Page: 255 - 266 Identifier: ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166