Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Measuring three-dimensional tibiofemoral kinematics using dual-slice real-time magnetic resonance imaging.

Lin, C. C., Zhang, S., Hsu, C. Y., Frahm, J., Lu, T. W., & Shih, T. F. (2019). Measuring three-dimensional tibiofemoral kinematics using dual-slice real-time magnetic resonance imaging. Medical Physics, 46(10), 4588-4599. doi:10.1002/mp.13761.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
3152652.pdf (Verlagsversion), 3MB
 
Datei-Permalink:
-
Name:
3152652.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt ( Max Planck Society (every institute); )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Lin, C. C., Autor
Zhang, S.1, Autor           
Hsu, C. Y., Autor
Frahm, J.1, Autor           
Lu, T. W., Autor
Shih, T. F., Autor
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Image registration; Knee; Real-time MRI; kinematics
 Zusammenfassung: PURPOSE:

The purpose of this study is to propose and evaluate a slice-to-volume registration (SVR) method integrating an advanced dual-slice real-time magnetic resonance image (MRI) and three-dimensional (3-D) MRI volume of the tibiofemoral joint for determining their 3-D kinematics.
METHODS:

The real-time and 3-D MRI of the knee were collected from twelve healthy adults at five static flexion positions and during dynamic flexion/extension movement. The 3-D positions and orientations of the femur and tibia were obtained by registering their volumetric models constructed from the 3-D MRI to dual-slice real-time MRI using an optimization process. The proposed method was quantitatively evaluated for its performance in terms of the robustness and measurement accuracy, and compared to those of a single-slice SVR method. Its repeatability in measuring knee kinematics during flexion/extension movement was also determined.
RESULTS:

In comparison to the single-slice SVR method, the dual-slice method was significantly superior, giving a successful registration rate > 95%, a bias less than 0.5 mm in translations and 0.6° in rotations and a precision less than 0.7 mm in translations and 0.9° in rotations for determining the 3-D tibiofemoral poses. For repeatability of the dual-slice SVR in measuring tibiofemoral kinematics during dynamic flexion-extension, the means of the time-averaged standard deviations were less than 0.9° for joint angles and 0.5 mm for joint translations.
CONCLUSION:

A dual-slice SVR method in conjunction with real-time MRI has been developed and evaluated for its performance in measuring 3-D kinematics of the tibiofemoral joint in twelve young adults in terms of the accuracy, robustness and repeatability. The proposed MRI-based 3-D measurement method provides a non-invasive and ionizing radiation-free approach for 3-D kinematic measurement of the tibiofemoral joint, which will be helpful for future academic and clinical applications.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2019-08-132019-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mp.13761
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Medical Physics
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 46 (10) Artikelnummer: - Start- / Endseite: 4588 - 4599 Identifikator: -