  Ultra-high resolution imaging of the human brain using acquisition-weighted imaging at 9.4 T

Budde, J., Shajan, G., Scheffler, K., & Pohmann, R. (2014). Ultra-high resolution imaging of the human brain using acquisition-weighted imaging at 9.4 T. NeuroImage, 86, 592-598. doi:10.1016/j.neuroimage.2013.08.013.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Budde, J1, 2, Author           
Shajan, G1, 2, Author           
Scheffler, K1, 2, Author           
Pohmann, R1, 2, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: One of the main goals of ultra-high field MRI is to increase the spatial resolution reached in structural and functional images. Here, the possibility to obtain in vivo images of the human brain with voxel volumes below 0.02 mm3 is shown at 9.4 T.
To optimize SNR and suppress ringing artifacts, an acquisition-weighted 3D gradient-echo sequence is used, which acquires more averages in the center than in the outer regions of k-space. The weighting function is adjusted to avoid losses in spatial resolution and scan duration compared to a conventional experiment with an equal number of scans and otherwise identical parameters. Spatial resolution and SNR of the weighted sequence are compared to conventionally acquired images by means of phantom and in vivo measurements, and show improved image quality with unchanged spatial resolution and an SNR increase of up to 36% in phantoms and 20% plusmn; 5% in vivo. Ultra-high resolution images with a voxel volume of 0.014 mm3 (0.13 ⁽×⁾ 0.13 ⁽×⁾ 0.8 mm3) from the human brain have sufficient SNR and show fine intracortical detail, demonstrating the potential of the technique.
The combination of acquisition-weighted imaging and highly sensitive array coils at ultra-high fields thus makes it possible to obtain images with ultra-high spatial resolutions within acceptable scan times.

Details

show
hide
Language(s):
 Dates: 2014-02
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.neuroimage.2013.08.013
BibTex Citekey: BuddeSSP2013_3
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: NeuroImage
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Orlando, FL : Academic Press
Pages: - Volume / Issue: 86 Sequence Number: - Start / End Page: 592 - 598 Identifier: ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166