日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Numerical Simulations of Intra-voxel Dephasing Effects and Signal Voids in Gradient Echo MR Imaging using different Sub-grid Sizes

Müller-Bierl, B., Graf H, Pereira, P., & Schick, F. (2006). Numerical Simulations of Intra-voxel Dephasing Effects and Signal Voids in Gradient Echo MR Imaging using different Sub-grid Sizes. Magnetic Resonance Materials in Physics, Biology and Medicine, 19(2), 88-95. doi:10.1007/s10334-006-0031-5.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Müller-Bierl, BM1, 著者           
Graf H, Pereira, PL, 著者
Schick, F, 著者
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Signal void artifacts in gradient echo imaging are caused by the intra-voxel dephasing of the spins. Intra-voxel dephasing can be estimated by computing the field distribution on a sub-grid inside each picture element, followed by integration of all magnetization components. The strategy of computing the artifacts based on the integration of the sub-voxel signal components is presented here for different sub-grids. The coarseness of the sub-grid is directly related to computational effort. The possibility to save memory space and computing time for the dipole model by computing the field only on a sub-grid is addressed in the presented article. It is investigated as to how far computational time and memory space can be reduced by using an appropriate sub-grid. Numerical results for a model of a partially diamagnetically coated needle shaft are compared to experimental findings. In the case of a pure titanium needle, it is shown as being sufficient to compute the field distribution on a sub-grid that is at least four times coarser in each direction than the grid used to discretize the object in the related MR image. Due to three nested loops over the 3D grid, the need for memory space and time is saved by a factor 64. Deviations between measurements and simulations for the broad side of the artifact (uncompensated) and for the small side of the artifact (compensated) were 15.5, respectively, 19.1 for orientation parallel to the exterior field, and 22.7, respectively, 23.1 for orientation perpendicular to the exterior field.

資料詳細

表示:
非表示:
言語:
 日付: 2006-05
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://www.springerlink.com/content/r034u113g51217ku/fulltext.pdf
DOI: 10.1007/s10334-006-0031-5
BibTex参照ID: 4820
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Materials in Physics, Biology and Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 19 (2) 通巻号: - 開始・終了ページ: 88 - 95 識別子(ISBN, ISSN, DOIなど): -