Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Intracranial electric field measurements during TES: Identifying determinant factors of the electric field distribution

Opitz, A., Yeagle, E., Thielscher, A., Schroeder, C., Mehta, A., & Milham, M. (2017). Intracranial electric field measurements during TES: Identifying determinant factors of the electric field distribution. Brain Stimulation, 10(4), e43-e43.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Meeting Abstract

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
Link (beliebiger Volltext)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Opitz, A, Autor           
Yeagle, E, Autor
Thielscher, A1, 2, Autor           
Schroeder, C, Autor
Mehta, A, Autor
Milham, MP, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Introduction Transcranial electric stimulation (TES) is an increasingly popular method to non-invasively modulate brain function. Recently, we have directly measured the electric field distribution in humans and non-human primates. However, in order to derive practical guidelines it is necessary to identify key factors that determine the electric field during TES in a given individual. Here, based on combined measurements and computational modeling, we identify determinant factors to be accounted for for a reliable application of TES. Methods One pre-surgical refractory epilepsy patient was implanted with subdural grid electrodes. In a single session two saline-soaked sponge electrodes (25cm 2) were attached to the scalp over the left and right temple. A 1Hz alternating current of 1mA was applied for 2 min with 10s ramp up/down. We measured the intracranial field distribution and created realistic FEM models. Results Inclusion of accurate skull and grid modeling had a marked effect on the correlation between simulated and measured electric fields, and only when accounting for both factors did we find high correlations between simulated and measured electric fields. Shifting the stimulation electrode further than 1 cm from its optimal location led to a breakdown of the correlations. Discussion We provide a direct validation of FEM models to predict electric fields in a surgical epilepsy patient. Further, we identified key factors needed for the accurate modeling of electric fields, including the precise representation of skull and ECOG grid. Our findings are a first step towards a reliable application of TES based on validated computational model.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2017-07
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1016/j.brs.2017.04.081
BibTex Citekey: OpitzYTSMM2017
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 3rd Meeting of the Biennial International Conference Focused on Technology and Mechanism for Advanced Brain Stimulation (NYC Neuromodulation 2017)
Veranstaltungsort: New York, NY, USA
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Brain Stimulation
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, NY : Elsevier
Seiten: - Band / Heft: 10 (4) Artikelnummer: - Start- / Endseite: e43 - e43 Identifikator: ISSN: 1935-861X
CoNE: https://pure.mpg.de/cone/journals/resource/1935-861X