English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Prussian Blue Modified Submicron Structured Gold Electrodes for Amperometric Hydrogen Peroxide Sensing

Lu, S.-Y., Chen, Y., Fang, X., & Feng, X. (2018). Prussian Blue Modified Submicron Structured Gold Electrodes for Amperometric Hydrogen Peroxide Sensing. Electroanalysis, 30(3), 583-592. doi:10.1002/elan.201700754.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Lu, Si-Yuan1, 2, Author           
Chen, Yihao1, 2, Author           
Fang, Xufei1, 2, 3, Author           
Feng, Xue1, 2, Author           
Affiliations:
1AML, School of Aerospace Engineering, Tsinghua University, Beijing, China, persistent22              
2Center for Advanced Mechanics and Materials, Tsinghua University, Beijing, China, persistent22              
3Nanotribology, Structure and Nano-/ Micromechanics of Materials, Max-Planck-Institut für Eisenforschung GmbH, Max Planck Society, ou_1863402              

Content

show
hide
Free keywords: -
 Abstract: In this work, we present a simple and effective approach for fabricating sub-micron structured gold (SM−Au) electrodes by chemically etching the magnetron co-sputtered gold film in KI solution for certain time. Such electrodes with a large surface area to volume ratio were used as the matrix for electrochemical deposition of Prussian blue (PB) to develop an electrochemical hydrogen peroxide sensor. Experimental characterization using scanning electron microscope and atomic force microscope shows that the thickness of PB layer on SM−Au electrode is around 140 nm, and is composited with cubic PB nanocrystals. The electrochemical performance of the designed sensor, studied using cyclic voltammograms and chronoamperometry methods, suggests that the sensor based on SM−Au/PB electrode presents the direct electron transfer of PB particle towards SM−Au film, and exhibits fast response, wide linearity, low detection limit and high stability. Under the optimized conditions, the sensitivity of the developed sensor for the detection of H2O2 reaches the value of 512 mA cm−2 M−1 with a linear range from 1 μM to 4.5 mM. © 2018 Wiley-VCH Verlag GmbH Co. KGaA, Weinheim

Details

show
hide
Language(s): eng - English
 Dates: 2018-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1002/elan.201700754
BibTex Citekey: Lu2018583
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Electroanalysis
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Weinheim, Germany : Wiley-VCH
Pages: - Volume / Issue: 30 (3) Sequence Number: - Start / End Page: 583 - 592 Identifier: ISSN: 1040-0397
CoNE: https://pure.mpg.de/cone/journals/resource/954925587333