English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  GLINT: Establishing reproducible APT-, NOE- and gluco-CEST measurement at 3 T: evaluated at 3 clinical sites

Deshmane, A., Zaiss, M., Herz, K., Rivlin, M., Kujawa, A., Kim, M., et al. (2019). GLINT: Establishing reproducible APT-, NOE- and gluco-CEST measurement at 3 T: evaluated at 3 clinical sites. Poster presented at 25th European Congress of Radiology (ECR 2019): The Bigger Picture, Wien, Austria. doi:10.26044/ecr2019/C-1311.

Item is

Files

show Files

Creators

show
hide
 Creators:
Deshmane, A1, 2, Author           
Zaiss, M1, 2, Author           
Herz, K1, 2, Author           
Rivlin, M, Author
Kujawa, A, Author
Kim, M, Author
Navon, G, Author
Golay, X, Author
Scheffler, K1, 2, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Aims and objectives:
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) allows for indirect detection of diluted molecules via their saturation transfer to the abundant water pool [1-3]. Many different diluted solutes were reported to be detectable with CEST, including endogenous solutes such [...]
Methods and materials:
MRI was performed at 3 T (Prisma, Siemens Healthcare) in three healthy subjects, each at a different clinical site: University College London (UCL), Max Planck Institute (MPI) for Biological Cybernetics in Germany, and Tel Aviv University (TAU) in Israel. In addition, one patient with one brain tum[...]
Results:
All three sites produced similar CEST contrasts with stable signal distribution over all slices. APT-weighted images exhibited the expected low contrast in healthy tissues (Figure 2). Spectrally selective amide- and NOE-CEST maps (Figure 3) showed gray- and white-matter contrast comparable to that r[...]
Conclusion:
At clinical field strengths, CEST effects are spectrally broadened and lower in magnitude, and therefore harder to isolate compared to experiments at ultra-high magnetic field strengths. Translation of CEST imaging to clinical field strengths is therefore challenging. In this study, a fast 3D snap[...]

Details

show
hide
Language(s):
 Dates: 2019-03
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.26044/ecr2019/C-1311
 Degree: -

Event

show
hide
Title: 25th European Congress of Radiology (ECR 2019): The Bigger Picture
Place of Event: Wien, Austria
Start-/End Date: 2019-02-27 - 2019-03-03

Legal Case

show

Project information

show

Source 1

show
hide
Title: 25th European Congress of Radiology (ECR 2019)
Source Genre: Proceedings
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: - Sequence Number: C-1311 Start / End Page: - Identifier: -