English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage

Juras, V., Bohndorf, K., Heule, R., Kronnerwetter, C., Szomolanyi, P., Hager, B., et al. (2016). A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage. European Radiology, 26(6), 1905-1912. doi:10.1007/s00330-015-3979-6.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Juras, V, Author
Bohndorf, K, Author
Heule, R1, Author           
Kronnerwetter, C, Author
Szomolanyi, P, Author
Hager, B, Author
Bieri, O, Author
Zbyn, S, Author
Trattnig, S, Author
Affiliations:
1University of Basel Hospital, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Objectives
To assess the clinical relevance of T2 relaxation times, measured by 3D triple-echo steady-state (3D-TESS), in knee articular cartilage compared to conventional multi-echo spin-echo T2-mapping.
Methods
Thirteen volunteers and ten patients with focal cartilage lesions were included in this prospective study. All subjects underwent 3-Tesla MRI consisting of a multi-echo multi-slice spin-echo sequence (CPMG) as a reference method for T2 mapping, and 3D TESS with the same geometry settings, but variable acquisition times: standard (TESSs 4:35min) and quick (TESSq 2:05min). T2 values were compared in six different regions in the femoral and tibial cartilage using a Wilcoxon signed ranks test and the Pearson correlation coefficient (r). The local ethics committee approved this study, and all participants gave written informed consent.
Results
The mean quantitative T2 values measured by CPMG (mean: 46±9ms) in volunteers were significantly higher compared to those measured with TESS (mean: 31±5ms) in all regions. Both methods performed similarly in patients, but CPMG provided a slightly higher difference between lesions and native cartilage (CPMG: 90ms→61ms [31%],p=0.0125;TESS 32ms→24ms [24%],p=0.0839).
Conclusions
3D-TESS provides results similar to those of a conventional multi-echo spin-echo sequence with many benefits, such as shortening of total acquisition time and insensitivity to B1 and B0 changes.

Details

show
hide
Language(s):
 Dates: 2016-06
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s00330-015-3979-6
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: European Radiology
  Other : Eur. Radiol.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Berlin : Springer International
Pages: - Volume / Issue: 26 (6) Sequence Number: - Start / End Page: 1905 - 1912 Identifier: ISSN: 0938-7994
CoNE: https://pure.mpg.de/cone/journals/resource/954925571877