English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Non-invasive Investigation of Intramyocellular and Extramyocellular Lipids in the Human Heart using Non-water-suppressed MR Spectroscopy

Hock, A., Fillmer, A., & Henning, A. (2015). Non-invasive Investigation of Intramyocellular and Extramyocellular Lipids in the Human Heart using Non-water-suppressed MR Spectroscopy. Magnetic Resonance Materials in Physics, Biology and Medicine, 28(Supplement 1), S297-S298.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Hock, A, Author
Fillmer, A, Author
Henning, A1, 2, Author           
Affiliations:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose/Introduction: Cardiac 1H MR-spectroscopy (MRS) is a promising tool for investigating human heart disease1. Previous MRS measurements localized in the human skeletal muscle allow a separation of intramyocellular lipids (IMCL)2 and extramyocellular lipids (EMCL)2 and it was shown that IMCL levels are related to insulin sensitivity (for a review3). In contrast, EMCL signal can change dramatically depending on the localization of the voxel e.g. due to inclusion of fascia, which might compromise the reproducibility of the measurement3. Therefore, for cardiac MRS an independent quantification of IMCL and EMCL would be ideal. However, spectral quality of cardiac MRS can be severely impaired by cardiac and respiratory motion, as well as by static field inhomogeneities making the separation difficult. This work presents the combination of imagebased B0-shimming4, ECG-triggering and navigator-gating along with retrospective frequency-alignment and phase-correction of metabolite-cycled (MC)5, non-water-suppressed MRS6,7 data, and demonstrates the feasibility for obtaining high quality spectroscopic information from the heart. Subjects and Methods: Measurements were performed at a 3 T Achieva system with a 32 channel cardiac coil (Philips Healthcare, Best, NL) in 8 healthy female volunteers. Navigator-gated bSSFP cine images were used for positioning the spectroscopy voxel (9.2 9 6.1 9 18.7 mm3) (Fig. 1) in the interventricular septum. Fig. 1 Measurement position in the human heart A linear shim for the heart was calculated using an image-based Shimtool8. The inner-volume saturated9 MC PRESS sequence6 (min. TR = min 3 heart beats, TE = 32 ms, C 512 averages) was ECGtriggered to end systole and the navigator position was recorded. MRecon (Gyrotools, Zurich, CH) was used to get access to raw data and for SVD coil combination. FIDs were zero filled to twice the original size, phase corrected, frequency-aligned and truncated and zero filled after 100 ms (Fig. 2). Resulting spectra were fitted with LCModel12. Results: Quantification results and an exemplary spectrum and fit are displayed in Fig. 3. The SNR of all measurements is 25 ± 11 and the line width is 21 ± 5 Hz (FWHM). IMCL and EMCL around 1.3 ppm can be resolved separately for the first time with CRLB of 2 and 15 , respectively. Additionally, creatine, trimethyl-ammonium compounds (TMA) and taurine can be detected with CRLBs\15 .

Details

show
hide
Language(s):
 Dates: 2015-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s10334-015-0489-0
BibTex Citekey: HockFH2015_2
 Degree: -

Event

show
hide
Title: 32nd Annual Scientific Meeting ESMRMB 2015
Place of Event: Edinburgh, UK
Start-/End Date: -

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Materials in Physics, Biology and Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 28 (Supplement 1) Sequence Number: - Start / End Page: S297 - S298 Identifier: -