Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  In-focus electron microscopy of frozen-hydrated biological samples with a Boersch phase plate

Barton, B., Rhinow, D., Walter, A., Schröder, R., Benner, G., Majorovits, E., et al. (2011). In-focus electron microscopy of frozen-hydrated biological samples with a Boersch phase plate. Ultramicroscopy, 111, 1696-1705.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Barton, B.1, Autor           
Rhinow, D.1, Autor           
Walter, A.1, Autor           
Schröder, R.2, Autor
Benner, G., Autor
Majorovits, E., Autor
Matijevic, M., Autor
Niebel, H., Autor
Müller, H., Autor
Haider, M., Autor
Lacher, M., Autor
Schmitz, S., Autor
Holik, P., Autor
Kühlbrandt, W.1, Autor           
Affiliations:
1Department of Structural Biology, Max Planck Institute of Biophysics, Max Planck Society, ou_2068291              
2Max Planck Society, ou_persistent13              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Electron cryo-microscopy; Phase plate; Electrostatic Einzel lens; Aberration correction; Phase contrast; Macromolecular complexes
 Zusammenfassung: We report the implementation of an electrostatic Einzel lens (Boersch) phase plate in a prototype transmission electron microscope dedicated to aberration-corrected cryo-EM. The combination of phase plate, Cs corrector and Diffraction Magnification Unit (DMU) as a new electron-optical element ensures minimal information loss due to obstruction by the phase plate and enables in-focus phase contrast imaging of large macromolecular assemblies. As no defocussing is necessary and the spherical aberration is corrected, maximal, non-oscillating phase contrast transfer can be achieved up to the information limit of the instrument. A microchip produced by a scalable micro-fabrication process has 10 phase plates, which are positioned in a conjugate, magnified diffraction plane generated by the DMU. Phase plates remained fully functional for weeks or months. The large distance between phase plate and the cryo sample permits the use of an effective anti-contaminator, resulting in ice contamination rates of <0.6nm/h at the specimen. Maximal in-focus phase contrast was obtained by applying voltages between 80 and 700 mV to the phase plate electrode. The phase plate allows for in-focus imaging of biological objects with a signal-to-noise of 5–10 at a resolution of 2–3 nm, as demonstrated for frozen- hydrated virus particles and purple membrane at liquid-nitrogen temperature.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2011
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: eDoc: 573931
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Ultramicroscopy
  Alternativer Titel : Ultramicroscopy
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 111 Artikelnummer: - Start- / Endseite: 1696 - 1705 Identifikator: -