  High-power 1H composite pulse decoupling provides artifact free exchange-mediated saturation transfer (EST) experiments.

Chakrabarti, K. S., Ban, D., Pratihar, S., Reddy, J. G., Becker, S., Griesinger, C., et al. (2016). High-power 1H composite pulse decoupling provides artifact free exchange-mediated saturation transfer (EST) experiments. Journal of Magnetic Resonance, 269, 65-69. doi:10.1016/j.jmr.2016.05.013.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2338347.pdf (Verlagsversion), 874KB
 
Datei-Permalink:
-
Name:
2338347.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (UNKNOWN id 303; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2338347_Suppl.pdf (Ergänzendes Material), 4MB
Name:
2338347_Suppl.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Chakrabarti, K. S.1, Autor           
Ban, D., Autor
Pratihar, S.1, Autor           
Reddy, J. G., Autor
Becker, S.1, Autor           
Griesinger, C.1, Autor           
Lee, D.1, Autor           
Affiliations:
1Department of NMR Based Structural Biology, MPI for biophysical chemistry, Max Planck Society, ou_578567              

Inhalt

einblenden:
ausblenden:
Schlagwörter: CEST; DEST; Decoupling; Dynamics; Exchange-mediated saturation transfer (EST); Relaxation
 Zusammenfassung: Exchange-mediated saturation transfer (EST) provides critical information regarding dynamics of molecules. In typical applications EST is studied by either scanning a wide range of (15)N chemical shift offsets where the applied (15)N irradiation field strength is on the order of hundreds of Hertz or, scanning a narrow range of (15)N chemical shift offsets where the applied (15)N irradiation field-strength is on the order of tens of Hertz during the EST period. The (1)H decoupling during the EST delay is critical as incomplete decoupling causes broadening of the EST profile, which could possibly result in inaccuracies of the extracted kinetic parameters and transverse relaxation rates. Currently two different (1)H decoupling schemes have been employed, intermittently applied 180° pulses and composite-pulse-decoupling (CPD), for situations where a wide range, or narrow range of (15)N chemical shift offsets are scanned, respectively. We show that high-power CPD provides artifact free EST experiments, which can be universally implemented regardless of the offset range or irradiation field-strengths.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2016-05-212016-08
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.jmr.2016.05.013
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Magnetic Resonance
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 269 Artikelnummer: - Start- / Endseite: 65 - 69 Identifikator: -