Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Analog phase lock between two lasers at LISA power levels

Diekmann, C., Steier, F., Sheard, B., Heinzel, G., & Danzmann, K. (2009). Analog phase lock between two lasers at LISA power levels. Journal of Physics: Conference Series, 154: 012020. doi:10.1088/1742-6596/154/1/012020.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
jpconf9_154_012020.pdf (Verlagsversion), 454KB
Name:
jpconf9_154_012020.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
eDoc_access: PUBLIC
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Diekmann, Christian1, Autor           
Steier, Frank1, Autor           
Sheard, Benjamin1, Autor           
Heinzel, Gerhard1, Autor           
Danzmann, Karsten1, Autor           
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: This paper presents the implementation of an analog optical phase-locked-loop with an offset frequency of about 20 MHz between two lasers, where the detected light powers were of the order of 31 pW and 200 mu W. The goal of this setup was the design and characterization of a photodiode transimpedance amplifier for application in LISA. By application of a transimpedance amplifier designed to have low noise and low power consumption, the phase noise between the two lasers was a factor of two above the shot noise limit down to 60 mHz. The achievable phase sensitivity depends ultimately on the available power of the highly attenuated master laser and on the input current noise of the transimpedance amplifier of the photodetector. The limiting noise source below 60 mHz was the analog phase measurement system that was used in this experiment. A digital phase measurement system that is currently under development at the AEI will be used in the near future. Its application should improve the sensitivity.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2009
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 435365
ISI: 10732355
DOI: 10.1088/1742-6596/154/1/012020
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Physics: Conference Series
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 154 Artikelnummer: 012020 Start- / Endseite: - Identifikator: -