日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Feedforward correction of mirror misalignment fluctuations for the GEO 600 gravitational wave detector

Smith, J. R., Grote, H., Hewitson, M., Hild, S., Lück, H., Parsons, M., Strain, K. A., & Willke, B. (2005). Feedforward correction of mirror misalignment fluctuations for the GEO 600 gravitational wave detector. Classical and Quantum Gravity, 22(14), 3093-3104.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
5_14_018.pdf (出版社版), 305KB
ファイルのパーマリンク:
https://hdl.handle.net/11858/00-001M-0000-0013-4DFA-4
ファイル名:
5_14_018.pdf
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
eDoc_access: PUBLIC
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Smith, J. R.1, 著者
Grote, Hartmut2, 著者           
Hewitson, Martin3, 著者           
Hild, Stefan2, 著者           
Lück, Harald2, 著者           
Parsons, M., 著者
Strain, Kenneth A.2, 著者           
Willke, Benno2, 著者           
所属:
1External Organizations, ou_persistent13              
2Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              
3Observational Relativity and Cosmology, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24011              

内容説明

表示:
非表示:
キーワード: -
 要旨: The core instrument of the GEO 600 gravitational wave detector is a Michelson interferometer with folded arms. The five main optics that form this interferometer are suspended in vacuum by triple pendulums with quasi-monolithic lower stages of fused silica. After installation of these pendulums in early 2003, a larger than expected coupling of longitudinal ground motion to tilt misalignment of the suspended optics was observed. Because of this, the uncontrolled misalignment of the optics during average conditions was several µrad Hz-1/2 in the frequency band around the pendulum resonance frequencies (0.5–4 Hz). In addition, it was found that longitudinal control signals applied to the intermediate pendulum stages also resulted in excessive mirror tilt. The resulting misalignment exceeded the level tolerable for stable operation of GEO 600. In order to reduce the level of mirror tilt, a bipartite feedforward system was implemented. One part feeds signals derived from seismic measurements to piezo-electric crystals in the stacks supporting the suspensions, reducing the longitudinal motion of the uppermost suspension points. The other applies tilt correction signals, derived from longitudinal control signals, to the intermediate level of the suspensions. The seismic feedforward correction reduces the root-mean-squared tilt misalignment of each main optic between 0.1 and 5 Hz by about 10 dB, typically. The intermediate-mass feedforward correction reduces the differential tilt misalignment of the Michelson interferometer by about 10 dB between 0.1 and 0.8 Hz, typically.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2005-07-21
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): eDoc: 251045
ISI: 000231036000020
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Classical and Quantum Gravity
  出版物の別名 : Class. Quantum Gravity
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 22 (14) 通巻号: - 開始・終了ページ: 3093 - 3104 識別子(ISBN, ISSN, DOIなど): ISSN: 0264-9381