English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Mass measurements of short-lived nuclides using the ISOLTRAP preparation Penning trap

Naimi, S., Rosenbusch, M., Audi, G., Blaum, K., Böhm, C., Borgmann, C., et al. (2011). Mass measurements of short-lived nuclides using the ISOLTRAP preparation Penning trap. Hyperfine Interactions, 199(1-3), 231-240. doi:10.1007/s10751-011-0318-4.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Naimi, S.1, Author
Rosenbusch, M.2, Author
Audi, G.1, Author
Blaum, Klaus3, Author           
Böhm, Christine3, Author           
Borgmann, Christopher3, Author           
Breitenfeldt, M.2, Author
George, Sebastian4, Author
Herfurth, Frank5, Author
Herlert, Alexander6, Author
Kowalska, Magdalena6, Author
Kreim, Susanne Waltraud3, Author           
Lunney, Dave1, Author
Minaya-Ramirez, E.1, Author
Neidherr, Dennis7, Author
Schweikhard, Lutz2, Author
Wang, Meng1, Author
Affiliations:
1CSNSM-IN2P3-CNRS, Université de Paris Sud, 91405 Orsay-Campus, France, ou_persistent22              
2Institut für Physik, Ernst-Moritz-Arndt-Universität, 17487 Greifswald, Germany, ou_persistent22              
3Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
4NSCL, Michigan State University, East Lansing, MI 48824, USA, ou_persistent22              
5GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt, Germany, ou_persistent22              
6Physics Department, CERN, 1211 Geneva 23, Switzerland, ou_persistent22              
7Institut für Physik, Johannes Gutenberg-Universität, 55128 Mainz, Germany, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: For exotic nuclear species, short decay half-lives make precision mass measurements particularly challenging. Combining isobaric purification and the mass measurement in the same trap may offer an interesting compromise between losses due to half-life and measurement precision. Here we discuss a mass measurement performed in a preparation Penning trap, and perform a study of the resonance lineshape.

Details

show
hide
Language(s): eng - English
 Dates: 2011-05-04
 Publication Status: Published online
 Pages: 10
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1007/s10751-011-0318-4
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Hyperfine Interactions
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Basel, Switzerland [etc.] : J.C. Baltzer [etc.]
Pages: - Volume / Issue: 199 (1-3) Sequence Number: - Start / End Page: 231 - 240 Identifier: ISSN: 0304-3843
CoNE: https://pure.mpg.de/cone/journals/resource/954925511444