English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Image restoration and spatial resolution in 7-Tesla magnetic resonance imaging

Lohmann, G., Bohn, S., Mueller, K., Trampel, R., & Turner, R. (2010). Image restoration and spatial resolution in 7-Tesla magnetic resonance imaging. Magnetic Resonance in Medicine, 64(1), 15-22. doi:10.1002/mrm.22488.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Green

Creators

show
hide
 Creators:
Lohmann, Gabriele1, Author           
Bohn, Stefan2, Author
Mueller, Karsten3, Author           
Trampel, Robert1, Author           
Turner, Robert1, Author           
Affiliations:
1Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634550              
2Innovation Center Computer Assisted Surgery (ICCAS), University of Leipzig, Germany, ou_persistent22              
3Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              

Content

show
hide
Free keywords: image restoration; high-field magnetic resonanceimaging; spatial resolution
 Abstract: A good spatial resolution is essential for high precision segmentations of small structures in magnetic resonance images. However, any increase in the spatial resolution results in a decrease of the signal-to-noise ratio (SNR). In this article, this problem is addressed by a new image restoration technique that is used to partly compensate for the loss in SNR. Specifically, a two-stage hybrid image restoration procedure is proposed where the first stage is a Wiener wavelet filter for an initial denoising. The artifacts that will inevitably be produced by this step are subsequently reduced using a recent variant of anisotropic diffusion. The method is applied to magnetic resonance imaging data acquired on a 7-T magnetic resonance imaging scanner and compared with averaged multiple measurements of the same subject. It was found that the effect of image restoration procedure roughly corresponds to averaging across three repeated measurements. Magn Reson Med 64:15-22, 2010. (C) 2010 Wiley-Liss, Inc.

Details

show
hide
Language(s): eng - English
 Dates: 2010-07
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.22488
PMID: 20577978
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 64 (1) Sequence Number: - Start / End Page: 15 - 22 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149